Page 6 - Cannon Integrated Outdoor Solutions 3Roda
P. 6

CANNON OUT DOOR RANGE

                                                                          E NV I R O NM E NTA L  S TA ND A R D S




           Electronics/electrical installations in outdoor         concerns mainly handles, locks, doors and
           environment need specific design measures               gaskets. The design of those parts shall provide
           especially if the place of installation is located in   access for maintenance under severe conditions
           public areas. With this focus IEC 61969-3 specifies     without degradation of the protection levels.
           the requirements and tests, in addition to the          Vandalism resistance shall be considered and
           contents of IEC 61587-1. Climatic test: The values      designed by using heavy latching, locking and
           of cold and heat, as well as protection against         hinge parts. For details see IEC 61969-1.
           wind driven rain are chosen in order to simulate
           harsh environment conditions, e. g. icing. This test








































                                                                                Seismic tests in accordance to
                                                                                IEC 61587-2

                                                                                The object of the seismic test is to
                                                                                prove physical integrity represented by
                                                                                a typical set-up, similar to the figure
                                                                                given under IEC 601587-1

                                                                                There are two severity levels indicating
                                                                                the requirements of different
                                                                                geographic regions: Japan and North
                                                                                America.
                                                                                The tests are passed if no deformation
                                                                                or damage can be detected affecting fit,
                                                                                form and function.

                                                                                Japan


      5                                                                         North America

                 T :   + 44( 0) 142 5 632600   |  CA N N ON T E CH . CO. U K   |  S A LE S @ CA N N ON T E CH . CO. U K