 FAN-PEDIA                                                                                SPARK RESISTANT
 Published by   AEROVENT.COM
 Aerovent                                                                                      CONSTRUCTION
 ©2017
                                                                                          RADIAL BLADED FANS


                                                                       AMCA Type C


                                       Type  C  offers  a  minimal  level  of  spark  resistance  and  only
                                       requires  that  possible  contact  between  stationary  and  rotating
                                       components be reduced. Typically, this construction includes the
 2
 1                                     use  of  an  aluminum  inlet  cone  and  an  aluminum  rub  ring.  The
                                       aluminum inlet cone will be the first point of fan wheel contact
 Typical Non Ferrous Materials
  -Aluminum                            if  there  is  a  mechanical  failure.  The  aluminum  rub  ring  placed
 -Aluminum/Nickel/Bronze               at the opening of the housing where the shaft passes, protects
 -Monel                                against contact of the steel fan shaft and steel fan housing.
 -Copper
 -Brass                                                       NON-FERROUS CONSTRUCTION
 -Bronze                                                                        1 - INLET PLATE
                                                                                  2 - RUB PLATE
                                                                             rub plate also know as
                                                                      STRIKER PLATE, SPARK PLATE
                                                                        3 - INNER DRIVE PLATE
                                                                                  4 - RUB RING

                                                                        STEEL CONSTRUCTION
 3
                                                                         - HOUSINGS / FRAME
                           4                                              - WHEEL / IMPELLER
 Construction varies by model.                                                    - FASTENERS
                                                                                    - PEDESTAL
                                                                                        -SHAFT


                                                             NOTE #1: BEARINGS NOT ALLOWED
                                                                                 IN AIRSTREAM


                                                   NOTE #2: IF FAN HAS A NON FERROUS WHEEL
                                                                      AS STANDARD, USE TYPE B