Page 177 - FanPedia - By Aerovent
P. 177

®
 FAN-PEDIA                                                                                SPARK RESISTANT
 Published by   AEROVENT.COM
 Aerovent                                                                                      CONSTRUCTION
 ©2017
                                                                                               PRESSURE BLOWERS

                                                                       AMCA Type C

 Typical Non Ferrous Materials
  -Aluminum                         Type  C  offers  a  minimal  level  of  spark  resistance  and  only
 2  -Aluminum/Nickel/Bronze         requires  that  possible  contact  between  stationary  and  rotating
 -Monel                             components be reduced. Typically, this construction includes the
 -Copper                            use  of  an  aluminum  inlet  cone  and  an  aluminum  rub  ring.  The
 -Brass                             aluminum inlet cone will be the first point of fan wheel contact
 -Bronze                            if  there  is  a  mechanical  failure.  The  aluminum  rub  ring  placed
                                    at the opening of the housing where the shaft passes, protects
                                    against contact of the steel fan shaft and steel fan housing.


                                                                NON-FERROUS CONSTRUCTION

                                                                             1 - INLET RUB RING
                                                                                    2 - RUB STRIP
                                                                                    3 - RUB RING


                                                                          STEEL CONSTRUCTION
                                                                           - HOUSINGS / FRAME
                  3
                                                                            - WHEEL / IMPELLER
                                                                                    - FASTENERS
 1                                                                                    - PEDESTAL
                                                                                          - STEEL


                                                               NOTE #1: BEARINGS NOT ALLOWED
                                                                                   IN AIRSTREAM

                                                     NOTE #2: IF FAN HAS A NON FERROUS WHEEL
 Construction varies by model.
                                                                        AS STANDARD, USE TYPE B







                                                                                                                                                   89