Page 181 - FanPedia - By Twin City Fan and Blower
P. 181
FAN-PEDIA SPECIAL CONSTRUCTION
Published by
Twin City Fan & Blower HIGH TEMPERATURE
©2017 TCF.COM
AXIAL FANS GENERAL INFORMATION
Industrial processes often require high heat
Arr. 4 fans that can withstand operating airstream
temperatures ranging from 106 F to 600 F.
o
o
TCF packages: High Temp Materials
• 106 F to 150 F • Standard Aluminum (Prop) – Up to 275 F
o
o
o
o
• 151 F to 195 F • A240 Aluminum – 276 F to 600 F
o
o
o
(Requires Eng Review) • Mild Steel & Stainless Steel
• 196 F to 240 F
o
o
(Requires Eng Review) Bearing Requirements
• Use High Temp Grease
• Use Fixed & Floating Bearings
> Refer to bearing basics section
• Metal lube lines
Other Requirements
• Prop on outlet end of housing (outer shell)
> Some models require Vane Section
• Fixed Prop required over 250 F
o
NOTE: Arr. 9 – Cool air is pulled into the bearing
Arr. 9 Retaining Washer Detail Vane Section housing through the belt tube
TCF packages:
• 201 F to 250 F
o
o
• 201 F to 300 F
o
o
(Select Fan Models)
Retaining Washer Safety Wire Hardware Shaft Cooler Heat Shield Belt Tube
(Select Arr. 9 Fans) (Arr. 9 only)
91