Page 181 - FanPedia - By Twin City Fan and Blower
P. 181

FAN-PEDIA                                                     SPECIAL CONSTRUCTION

 Published by
 Twin City Fan & Blower                                                                              HIGH TEMPERATURE
 ©2017   TCF.COM
 AXIAL FANS                                                     GENERAL INFORMATION

                                                                Industrial  processes  often  require  high  heat
 Arr. 4                                                         fans  that  can  withstand  operating  airstream
                                                                temperatures ranging from 106 F to 600 F.
                                                                                                                        o
                                                                                                                                        o
 TCF packages:                                                  High Temp Materials
 •  106 F to 150 F                                              •  Standard Aluminum (Prop) – Up to 275 F
 o
 o
                                                                                                                                         o
 o
 •  151 F to 195 F                                              •  A240 Aluminum – 276 F to 600 F
 o
                                                                                                           o
                                                                                                                           o
     (Requires Eng Review)                                      •  Mild Steel & Stainless Steel
 •  196 F to 240 F
 o
 o
     (Requires Eng Review)                                      Bearing Requirements
                                                                •  Use High Temp Grease
                                                                •  Use Fixed & Floating Bearings
                                                                               > Refer to bearing basics section
                                                                •  Metal lube lines
                                                                Other Requirements
                                                                • Prop on outlet end of housing (outer shell)
                                                                                > Some models require Vane Section
                                                                • Fixed Prop required over 250 F
                                                                                                                       o
                                                                 NOTE: Arr. 9 – Cool air is pulled into the bearing
 Arr. 9  Retaining Washer Detail  Vane Section                  housing through the belt tube






 TCF packages:
 •  201 F to 250 F
 o
 o
 •  201 F to 300 F
 o
 o





 (Select Fan Models)
              Retaining Washer                Safety Wire                Hardware                  Shaft Cooler                   Heat Shield                  Belt Tube
 (Select Arr. 9 Fans)                       (Arr. 9 only)
                                                                                                                                                   91