FAN-PEDIA                                                     SPECIAL CONSTRUCTION

 Published by
 Twin City Fan & Blower                                                                                      INSULATED FANS
 ©2017   TCF.COM

 CENTRIFUGAL FANS
 Aluminum Clad Construction                                     GENERAL INFORMATION

                                                                Purpose:            Insulate          fan       surface          from         high
                                                                temperature, condensation or sound.

                                                                Overview
                                                                •  Insulation  thickness  per  customer  request  &
                                                                     Aerovent guidelines
                                                                •  Exterior              cladding            material            is       0.040”
                                                                     (minimum) thick stucco-embossed aluminum
                                                                •  Insulation  type  (provided  by  vendor):    3#
                                                                     density  fiberglass  or  mineral  wool  unless
                                                                     otherwise specified
                                                                •  Raised  Access  Door  (usually  raised  2”  above
                                                                     insulation)
                                                                •  Housing  Drain  –  Normally  extends  out  inlet
                                                                     end of housing (shown on bottom in photo)
                                                                •  Inlet & Outlet of fan extended if required
                                                                •  Fan centerline height increased if required
                                                                •  Housing  Split  (if  specified)  to  have  split  bars
                                                                     protruding out 2” past insulation for access to
                                                                     mounting holes
                                                                •  Cooler box on high temperature applications














 Shaft Seal                Shaft Cooler         Cooler Box                    Cooler Guard              Insulation            Insulation Pins

 Access Door         Lifting Lugs/Extended Frame         Extended Drain                 Aluminum Clad Housing