         Important requirements for the use of compressed

         air equipment


         To maintain performance and avoid damage, the compressed air that is supplied must meet certain requirements. Precise
         operating conditions are of paramount importance. It is recommended that you use complete maintenance units consisting of
         water trap (filter), pressure reducer with pressure gauge and oiler.
         Air pressure
         At the connecting sleeve, 5 - 10 bar (ATU) is required, depending on the device type. Insufficient pressure reduces performance. Too much
         pressure results in excessive wear and premature failure of the devices.
         Air flow rate:
         The individual devices are equipped with different-sized air motors. Proper function requires the use of hoses with the recommended
         cross-section part (depending on device type nominal size DN diameter 8 - 13 mm) and an adequate compressor performance (compressor
          suction is not the same as compressor effective power).
         Condensation
         Moisture endangers the lubrication and causes corrosion in the tool. Water separators that are in perfect working order are absolutely
         necessary. Freezing of the pipe system results in cross-sectional constrictions which causes loss of pressure and flow rate quantity

         Oil supply
         Continuous lubrication of the air motor is critical. If no line oiler is available, then 1 - 2 cc of air oil must be added to the air hose every day before
         starting work.

         Device manual
         Please follow the operating and maintenance instructions that come with each UNIT.
         Air requirement calculation / compressor size
         The following example shows how connecting a consumer puts a load on the compressor's capacity.

                     Reservoir volume x (shut-off pressure - working pressure)
         Work time =
                       (tool air consumption) - (delivery quantity compressor

                   500 l × (10 – 6)
         Example:               =  Max. 8 min. constant operating timer
                    500 – 250