Page 349 - Basic Electrical Engineering
P. 349

lagging the reference axis by 22.6° as shown in Fig. 3.43. The angle between
               phasor V and phasor I is 69.4°. This is the power factor angle.


               Power factor,



                         cos ϕ = cos69.4°
                                  = 0.35 lagging























                                                          Figure 3.43


               Power consumed,


                                   P = VIcosϕ

                                   P = 233 × 19.2 × 0.35
                                      = 1565.76 W



               If supply frequency is taken as 50 Hz, the value of L can be calculated from

               X .
                  L
   344   345   346   347   348   349   350   351   352   353   354