Page 19 - Fuel Cell Student Edition
P. 19

12.  Connect the multimeter to the fuel cell. Measure   15.  Present your group’s optimized design ideas to
                 the potential (V), record it, then measure the     the class.
                 current draw by plugging the red multimeter
                 lead into to the current port on the multimeter.   16. To scale the fuel cell data for use in the
                 Some multimeters will allow you to keep it         optional modeling lab, multiply your current in
                 plugged into the voltage port. The range for       milliamps by 6 and your voltage by 75.
                 measuring current is 0-99mA.

             13.  Calculate the fuel cell power (mW) by
                 multiplying the potential (V) and the current       For example, if your fuel cell output
                 (mA).                                               is 25mA at 1.2V, then the scaled data
                                                                     for the fuel cell modeling lab would be
             14. Discuss with your group members how the             150A at 90V.
                 cell design may be optimized.




























































 18  TOTAL REDOX™ – FUEL CELLS                                                    TOTAL REDOX™ – FUEL CELLS   19
   14   15   16   17   18   19   20   21   22   23   24