For SAR Floors SPC Click Floating Products
General Information
•All instructions and recommendations should be followed for a satisfactory installation. A minimum of a 48-
hour acclimation period of the material is required prior to installation. The floor covering should be acclimated
and installed in a climate-controlled environment with a temperature between 55 degrees and 85 degrees
Fahrenheit, (13 degrees – 29 degrees Celsius) or average temperature of 70 degrees, (21.1 Celsius)
• Post installation temperature range is between -25- and 140-degrees F (-31.6°- 60°C).
• Avoid exposure to direct sunlight for prolonged periods, doing so may result in discoloration. During peak
sunlight hours, the use of the drapes or blinds is recommended. Excess temperature due to direct sunlight can
result in thermal expansion and UV fading.
• Install product after all other trades have completed work that could damage the flooring. If cabinets are to
be installed on top of the flooring (including islands), that area of material must be fully adhered to the subfloor
(including an additional 2’ft beyond the cabinets and islands).
• To minimize shade variation, mix and install planks from several cartons. Inspect all planks for damage before
installing. If you have any concerns about the product fit or finish, SAR Floors Technical support. Claims will not
be accepted for flooring that has been cut to size and/or installed.
• Use cementations patching and leveling compounds that meet or exceed maximum moisture level and pH
requirements. Use of gypsum-based patching and/or leveling compounds which contain Portland or high
alumina cement and meet or exceed the compressive strength of 3,000 psi are acceptable.
• Installation Methods: Floating (on, above or below grade) / Glue Down (on, above or below grade)
• For installation in areas larger than 50’x 50’, 2500 sq. ft. provide a minimum expansion space of 1/2” (12.7
mm)
around the Perimeter.
• This flooring is waterproof and reliably secures the flooring panels on all four sides. However, excessive
moisture
in the subfloor could promote mold, mildew, and other moisture related issues like the trapping of moisture
emissions under the flooring, which may contribute to an unhealthy indoor environment.
• Additional layer of 5mil poly film or equal vapor retarder with a perm rating of 1 or less may be used as an
additional layer of protection.
• A second underlayment is allowed under any currently sold SPC Product with attached underlayment in a
residential application. If installed over a second underlayment, this underlayment cannot be greater than 3
mm thick. IIC. (ASTM E492-09) and STC (ASTM E90-09) lab testing on certain SPC products tested with and
without a second layer of underlayment, to date, does not indicate that a second underlayment will provide
additional acoustic benefit.