                Fire Extinguishers- Foam


                                                  C               Part No.       A   B   C       Rating    Kg       Size
                                                                  900AF         345  95  95      5A-34B    2.25    1Ltr
                                                                  900AF-C       345  95  95      5A-34B    2.27    1Ltr
                                                                  2000AF        387  120  115      8A-55B   3.93   2Ltr
                                                       A          2000AF-C      387  120  115      8A-55B   4.15   2Ltr
                                                                  Part No. 900AF/C and 2000AF/C supplied with integrated central
                                                                  clamp and transport bracket.
                                                                  1L fire extinguishers are manufactured in accordance with BS
                                                                  EN3-7 Excluding clause 6.1.  2L Extiguishers have full  BS EN3-7
                                                  B                certification.


                Fire Extinguishers- Dry Powder


                                                  C               Part No.       A   B   C       Rating    Kg       Size
                                                                  1000DP-C      347  95  90      8A-55B    2.21    1kg
                                                                  2000DP-C      392  120  120      13A-70B   4.07   2kg
                                                                  6000DP        540  185  215      27A-44B   9.92   6kg
                                                                  9000DP        580  230  245      55A-233B   13.98   9kg
                                                       A
                                                                  6000DP and 9000DP supplied complete with hose - No bracket.
                                                                  Part No.1000DP/C 2000DP/C Supplied with integrated central clamp
                                                                  and transport bracket.
                                                                  All Dry Powder extinguishers listed have full  BS EN3-7 certification.
                                                  B


                Fire Extinguisher Boxes



                                                                  Part No.       A   B   C   D   E   F   G   H   Kg  Finish
                                                                  FEB65         650  260  240  260  275            3.49   RP
                                                           D      FEB75         750  300  270  300  300            4.67   RP
                                                                  Manufactured from medium density recyclable polyethylene.
                                               A       C       E  For 6kg extinguisher FEB65.
                                                                  For 9kg extinguisher FEB75.

                                                   B





                Underbonnet Fire Suppression System



                                                                  Part No.       A   B   C   D   E   F   G  H  Kg  Voltage
                                                 A
                                          B              C        FlameChoke  2500  44  67  23  18  21  23     1.02   12/24
                                                                  FlameChoke 3 3000  44  67  23  18  21  23  1.17   12/24
                                                                  The FlameChoke detection tube is filled with FE-36 which is an
                                                                  extremely effective, clean and people-safe extinguishing medium.
                                         D      E     F    G      Importantly the fluid itself does not conduct electricity or cause
                                                                  thermal shock damage. It is therefore perfectly safe to use on
                                                                  electrical fires and won’t damage your engine.