Page 45 - DMcatalogue2017
P. 45

Low voltage AC drives

         ABB general purpose drive

         ACS580-01 – Dimensions and options






         Dimensions and weights, wall-mounted drives

                        IP21                                                  IP55
         Frame   Height  Width  Depth  Weight                  Frame   Height  Width  Depth  Weight
         size    mm     mm    mm      kg                       size    mm     mm    mm      kg
         R0      303    125   210     4.5                      R0      303    125   222    5.1
         R1      303    125   223     4.6   H                  R1      303    125   233    5.1    H
         R2      394    125   227     7.5                      R2      394    125   239    8.0
         R3      454    203   228    14.9                      R3      454    203   237    15.4                      4
         R4      600    203   258     19                       R4      600    203   265     20
         R5      732    203   283     23                       R5      732    203   320     29
         R6      727    252   369     45                       R6      726    252   380    45.5
         R7      880    284   370     55                       R7      880    284   381    55.5
         R8      965    300   393     70                       R8      965    300   452     72
                                               D                                                      D
                                                         W                                                     W
                                                    IP21                                                  IP55
         Options for ACS580-01                                 Typical I/O connections for ACS580
         ACS580-01 is a wall mounted drive, so all options     These connections are shown as examples only. Please
         fit inside:                                           refer to the User’s Manual – macro section, for more detailed
         – IP55 variant                                        information and for different I/O configurations.
         – Internal fieldbus options
         –  Optional additional industrial fieldbus                       X1  Meaning  Default macro connections
         – Optional relay expansion                                        1  2   SCR   Signal cable shield (screen)
                                                                                  External frequency reference 1: 0 to 10 V
                                                                               AI1
         – Optional isolated PTC option                                    3   AGND   Analogue input circuit common
                                                                           4   +10V   Output reference voltage 10 V DC
         – Optional 115/230 V digital inputs                   1 to 10 kohm  5   AI2   Analogueue input (not used)
         – UK gland box to accommodate SWA cable                           6  7   AGND   Analogue input circuit common
                                                                                  Output frequency: 0 to 20 mA
                                                                               AO1
         – Brake chopper (up to frame R3 fitted as standard)               8   AO2   Output current: 0 to 20 mA
                                                                           9   AGND   Analogue output circuit common
         Apart from IP55, the above also applies to ACS580-04    max. 500 ohm  S3   AO1 I/U   Voltage/Current selection for analogue output
         and ACS580-07.                                                  X2 & X3   Aux. voltage output and programmable digital inputs
                                                                               +24V
                                                                                  Auxiliary voltage output +24 V DC
                                                                           10
                                                                           11   DGND   Auxiliary voltage output common
                                                                           12   DCOM   Digital input common for all DI
         All ABB general purpose drives use the same common                13   DI1   Start/Stop: Activate to start
         options and user interfaces. These are detailed on page 46.       14   DI2   Fwd/Rev: Activate to reverse rotation direction
                                                                           15
                                                                               DI3
                                                                                  Constant speed selection
         They are also part of the “all compatible family” so keypad       16   DI4   Constant speed selection
                                                                           17
                                                                               DI5
                                                                                  Ramp pair selection: Activate to select
         interfaces, common PC tools, parameter structures and                    second pair
                                                                           18   DI6   Not used
         programing methods are all common, even across other            X6, X7, X8  Relay outputs
         drive ranges.                                                     19   RO1C                      Ready
                                                                           20   RO1A                     250 V AC/30 V DC
                                                                           21   RO1B                     2 A
                                                                           22   RO2C                     Running
         Cold configuration adapter – CCA-01                               23   RO2A                     250 V AC/30 V DC
         ACS580 drives can be programmed without the need for              24   RO2B                     2 A
                                                                               RO3C
                                                                           25
                                                                                                      Fault (-1)
         mains power or without taking the drive out of the box using      26   RO3A                     250 V AC/30 V DC
                                                                           27   RO3B                     2 A
         the CCA-01. This specifically allows rapid programming for       X5   EIA-485 Modbus RTU
         OEM without the need for safe areas in production.                29   B+
                                                                           30   A-  Built-in Modbus RTU fieldbus interface
                                                                           31   DGND
                                                                          S4   TERM  Serial data link termination switch
                                                                          S5   BIAS  Serial data link bias resistors switch
                                                                           X4   Safe torque-off
                                                                           34   OUT1
                                                                           35   OUT2
                                                                           36   SGND  Safe torque-off. Both circuits must be closed for the drive to start. The circuits are
                                                                                  closed with jumper wires in the standard delivery.
                                                                           37   IN1
                                                                           38   IN2
                                                                          X10  24 V AC/DC*
                                                                           40  24 V  AC/DC-in. Ext. 24 V AC/DC input to power up the control unit when the main supply
                                                                                  is disconnected
                                                                           41  24 V  AC/DC+in.
                                                                        *Standard on R6 frames and above and is optional on smaller frames
                                                                        (requires a CMOD)
                                                           Drives and controls, motors and mechanical power transmission catalogue  45
   40   41   42   43   44   45   46   47   48   49   50