Low voltage AC drives
ABB drive for HVAC
ACH580-01 – Dimensions and options
Dimensions and weights, wall-mounted drives
IP21 IP55
Frame Height Width Depth Weight Frame Height Width Depth Weight
size mm mm mm kg size mm mm mm kg
R0 303 125 210 4.5 R0 303 125 222 5.1
R1 303 125 223 4.6 H R1 303 125 233 5.1 H
R2 394 125 227 7.5 R2 394 125 239 8.0
R3 454 203 228 14.9 R3 454 203 237 15.4 4
R4 600 203 258 19 R4 600 203 265 20
R5 732 203 283 23 R5 732 203 320 29
R6 727 252 369 45 R6 726 252 380 45.5
R7 880 284 370 55 R7 880 284 381 55.5
R8 965 300 393 70 R8 965 300 452 72
R9 955 380 418 98 D R9 955 380 477 100 D
W W
IP21 IP55
Options for ACH580-01 Typical I/O connections for ACH580
ACH580-01 is a wall mounted drive, so all of the options These connections are shown as examples only. Please
fit inside: refer to the User’s Manual – macro section, for more detailed
– IP55 variant information and for different I/O configurations.
– Internal fieldbus options
– Optional additional industrial fieldbus X1 Meaning Default connections
1 SCR Signal cable shield (screen)
– Optional relay expansion 2 AI1 External frequency reference 1: 0 to 10 V
3 AGND Analogue input circuit common
– Optional isolated PTC option 4 +10V Output reference voltage 10 V DC
– Optional 115/230 V digital inputs 1 to 10 kohm 5 AI2 Analogueue input (not used)
6 AGND Analogue input circuit common
– UK gland box to accommodate SWA cable 7 AO1 Output frequency: 0 to 20 mA
8 AO2 Output current: 0 to 20 mA
– Brake chopper (up to frame R3 fitted as standard) 9 AGND Analogue output circuit common
max. 500 ohm S3 AO1 I/U Voltage/Current selection for analogue output
X2 & X3 Aux. voltage output and programmable digital inputs
All ABB HVAC drives use the same common options and user 10 +24V Auxiliary voltage output +24 V DC
11 DGND Auxiliary voltage output common
interfaces. These are detailed on page 50. They are also part 12 DCOM Digital input common for all DI
of the “all compatible family” so keypad interfaces, common 13 DI1 Start/Stop: Activate to start
14 DI2 Not configured
PC tools, parameter structures and programing methods are 15 DI3 Constant speed selection
all common. 16 DI4 Not configured
17
Not configured
DI5
18 DI6 Not configured
X6, X7, X8 Relay outputs
Cold configuration adapter – CCA-01 19 RO1C Ready
ACH580 drives can be programmed without the need for 20 RO1A 250 V AC/30 V DC
2 A
21
RO1B
mains power or without taking the drive out of the box using 22 RO2C Running
250 V AC/30 V DC
23
RO2A
the CCA-01. This specifically allows rapid programming for 24 RO2B 2 A
OEM without the need for safe areas in production. 25 RO3C Fault (-1)
RO3A
250 V AC/30 V DC
26
27 RO3B 2 A
X5 EIA-485 Modbus RTU
29 B+
30 A- Embedded modbus
31 DGND
S4 TERM Serial data link termination switch
S5 BIAS Serial data link bias resistors switch
X4 Safe torque-off
34 OUT1
35 OUT2
36 SGND Safe torque-off. Both circuits must be closed for the drive to start. The circuits are
closed with jumper wires in the standard delivery.
37 IN1
38 IN2
X10 24 V AC/DC*
40 24 V AC/DC-in. Ext. 24 V AC/DC input to power up the control unit when the main supply
is disconnected
41 24 V AC/DC+in.
*Standard on R6 frames and above and is optional on smaller frames
(requires a CMOD)
Drives and controls, motors and mechanical power transmission catalogue 49