FLEXIBLE FASCIA INSTALLATION
INSTALLING FASCIA
STEP 4
Unroll the flexible fascia and align the
“Start of Fascia” marker at the left hand
corner. Using clamps with protective ends,
clamp the flexible face to the top extrusion.
STEP 5
ROD INSTALLATION INSTRUCTIONS
FOR FLEXIBLE FASCIA
Cut a 1/4" slit through the sewn hem of the
flexible fascia. It is important that you do
not cut through the sewn hem or welded
seam.
STEP 6
Insert one 1/4" x 6' plated steel rod into the
hem at the top, and insert one 1/4" x 6'
plated steel rod into the hem at the bottom.
NOTE: The rod should be cut 2 inches short
of a corner. This will allow room for the flexible
fascia and springs to fold over and not double
up at the corner.