                               DURO-GUARD  SECUROCK  GLASS-MAT 5/8-INCH ROOF BOARD

            Installation:
                                                                      Subsequent layers of insulation and approved
                 In steel deck applications, refer to Table 1 for    cover boards may be attached with insulation
                 flute spanability.                                   adhesive.

                 Panels must be kept dry before, during and      Hot Bitumen Attachment
                 after installation. Install only as much insulation
                 as can be covered the same day with                  When using hot bitumen on concrete decks,
                                                                      priming is necessary.
                 completed roofing.
                                                                      Temperature of the bitumen shall be
                 The use of multiple layers of insulation with
                 joints staggered a minimum of 6 inches               approximately 50° F below the inter-ply hand
                                                                      mopping EVT.
                 between layers is recommended to eliminate
                 thermal bridging.                                    The deck shall be dry and care must be taken
                                                                      to apply the bitumen in sufficient quantity to
                 Abut panel edges loosely (minimum of 1/16-          totally cover the available deck surface.
                 inch gap on all sides) and stagger joints of
                 adjacent panels. Gaps may need to be larger          To ensure embedment, the board shall also be
                 depending on factors like the roof deck's size,      “stepped in” at several points while the bitumen
                 membrane color, deck surface temperature and         is still hot enough to allow positive attachment.
                 time of year the roof assembly is installed.
                                                                      Any roof membrane contaminated with bitumen
                 Gaps must be no greater than 1/4 inch around        must be replaced.
                 all penetrations.
                                                                 Storage:
                 Refer to the appropriate Duro-Last roof system
                 specification and detail drawings for deck           Must be protected from open flame and kept
                 preparation and attachment requirements.             dry at all times.
                 Precautions must be taken to ensure that new        Factory applied packaging is intended only for
                 concrete decks have fully hydrated and do not        protection during transit. Slit or remove the
                 continue to release moisture.                        packaging to prevent accumulation of
                                                                      condensation.
            Panel Attachment:
                                                                      Store elevated (at least 3 inches) and
                 Panels may be attached to the roof deck using       completely covered with a weatherproof
                 mechanical fasteners, insulation adhesive or         covering such as a tarpaulin.
                 hot bitumen. It is acceptable to use these
                 products in combination.                             Do not use panels which are wet or damaged.
             Mechanical Attachment                                    Refer to PIMA Technical Bulletin No. 109:
                                                                      Storage and Handling Recommendations for
                 When installing multiple layers (which may          Polyiso Roof Insulation for additional guidelines
                 include insulation, cover boards and thermal         (www.pima.org).
                 barriers) it is acceptable to mechanically secure
                 through all layers.                             Limitations:

                 Use fasteners and plates supplied by or             Duro-Last, Inc. will not be responsible or liable
                 approved by Duro-Last, Inc.                          for any defects or problems related to building
                                                                      or roof design by others, to deficiencies in
             Adhesive Attachment                                      construction, to dangerous conditions on the
                                                                      job site, or to improper storage, handling or
                 Insulation adhesive must be supplied by Duro-
                 Last, Inc. Refer to the adhesive’s Product Data      installation by others.
                 Sheet for application guidelines. Acceptable
                 products:
                            ®
                 o Duro-Grip  Insta-Stik™.
                                       ®
                 o Duro-Grip Olybond500 .
                                                 ®
                 o Duro-Grip Millenium Weather-Tite .
                 o Duro-Grip CR-20.




               www.duro-last.com                            2 of 2                             800-248-0280
           Duro-Last, Duro-Guard, Duro-Grip, Duro-Bond and “World’s Best Roof” are registered marks owned by Duro-Last, Inc. Weather-Tite is a registered mark owned by Millenium Adhesive Company.
                  Securock is a registered mark owned by USG Corporation. RoofNav is a registered mark owned by FM Global. Olybond500 is a registered mark owned by OMG, Inc.
                                                   Created: 01/12/2015 Revised: 05/07/2015
   103   104   105   106   107   108   109   110   111   112   113