                                     DURO-GUARD  REWALL  HALFBACK ROOF BOARD
            Installation:
                                                                  Hot Bitumen Attachment
                 In steel deck applications, refer to Table 1 for
                 flute spanability.                                   When using hot bitumen on concrete decks,
                                                                      priming is necessary.
                 Panels must be kept dry before, during and
                 after installation. Install only as much insulation      Temperature of the bitumen shall be
                                                                      approximately 50° F below the inter-ply hand
                 as can be covered the same day with
                 completed roofing.                                   mopping EVT.
                                                                      The deck shall be dry and care must be taken
                 The use of multiple layers of insulation with       to apply the bitumen in sufficient quantity to
                 joints staggered a minimum of 6 inches
                 between layers is recommended to eliminate           totally cover the available deck surface.
                 thermal bridging.                                    To ensure embedment, the board shall also be
                                                                      “stepped in” at several points while the bitumen
                 Abut panel edges loosely (minimum of 1/16-
                 inch gap on all sides) and stagger joints of         is still hot enough to allow positive attachment.
                 adjacent panels. Gaps may need to be larger          Any roof membrane contaminated with bitumen
                 depending on factors like roof deck size,            must be replaced.
                 membrane color, deck surface temperature and
                 time of year the roof assembly is installed.    Storage:
                 Gaps must be no greater than 1/4 inch around        Must be protected from open flame and kept
                 all penetrations.                                    dry at all times.

                 Refer to the appropriate Duro-Last roof system      Factory-applied packaging is intended only for
                 specification and detail drawings for deck           protection during transit. Slit or remove the
                 preparation and attachment requirements.             packaging to prevent accumulation of
                                                                      condensation.
                 Precautions must be taken to ensure that new
                 concrete decks have fully hydrated and do not        Store elevated (at least 3 inches) and
                 continue to release moisture.                        completely covered with a weatherproof
                                                                      covering such as a tarpaulin.
            Panel Attachment:
                                                                      Do not use panels which are wet or
                 Panels may be attached to the roof deck using       damaged.
                 mechanical fasteners, insulation adhesive or
                 hot bitumen. It is acceptable to use these           Refer to PIMA Technical Bulletin No. 109:
                 products in combination.                             Storage and Handling Recommendations for
                                                                      Polyiso Roof Insulation for additional guidelines
             Mechanical Attachment                                    (www.pima.org).

                 When installing multiple layers (which may
                 include insulation, cover boards and thermal    Limitations:
                 barriers) it is acceptable to mechanically secure      Duro-Last, Inc. will not be responsible or liable
                 through all layers.                                  for any defects or problems related to building
                 Use fasteners and plates supplied by, or            or roof design by others, to deficiencies in
                 approved by Duro-Last, Inc.                          construction, to dangerous conditions on the
                                                                      job site, or to improper storage, handling or
             Adhesive Attachment                                      installation by others.
                 Insulation adhesive must be supplied by Duro-
                 Last, Inc. Refer to the adhesive’s Product Data
                 Sheet for application guidelines. Acceptable
                 products:
                            ®
                 o Duro-Grip  insulation adhesives
                 Subsequent layers of insulation and approved
                 cover boards may be attached with insulation
                 adhesive.







               www.duro-last.com                            2 of 2                             800-248-0280