Page 101 - Microsoft Word - 2_Inch_Drain_Adapter_PDS_2016_01_05
P. 101

®
                                                   DURO-GUARD  ISO NB
            Installation:
                                                                  TABLE 2.  TYPICAL PHYSICAL PROPERTIES (FOAM CORE)
                 Panels must be kept dry before, during and
                 after installation. Install only as much insulation                          Grade 2    20 psi
                 as can be covered the same day with               Compressive   ASTM D 1621            (138 kPa)
                                                                                 ASTM C 1289
                                                                     Strength
                                                                                                         25 psi
                 completed roofing.                                                           Grade 3   (172 kPa)
                 The use of multiple layers of insulation with    Dimensional   ASTM D 2126     2% linear change
                                                                     Stability
                                                                                                    (7 days)
                 joints staggered a minimum of 6 inches
                                                                                                    < 1 perm
                 between layers is recommended to eliminate       Moisture Vapor   ASTM E 96    (57.5 ng/Pa·s·m )
                                                                                                            2
                                                                   Transmission
                 thermal bridging.
                                                                      Water
                 Abut panel edges together and stagger joints of   Absorption   ASTM C 209       < 1% volume
                 adjacent panels.                                    Service                     -100° to 250° F
                                                                   Temperature                   (-73° to 122° C)
                 Boards must be neatly fitted to roof deck and
                 around penetrations with no gaps greater than
                 ¼ inch.
                                                                      The deck shall be dry and care must be taken
                 Refer to the appropriate Duro-Last roof system      to apply the bitumen in sufficient quantity to
                 specification and detail drawings for deck           totally cover the available deck surface.
                 preparation and attachment requirements.
                                                                      To ensure embedment, the board shall also be
                 Precautions must be taken to ensure that new        “stepped in” at several points while the bitumen
                 concrete decks have fully hydrated and do not        is still hot enough to allow positive attachment.
                 continue to release moisture.
                                                                      Maximum panel dimensions are 4 ft. x 4 ft.
            Panel Attachment:                                         Any roof membrane contaminated with bitumen
                                                                      must be replaced.
                 Panels may be attached to the roof deck using
                 mechanical fasteners, insulation adhesive or    Storage:
                 hot bitumen. It is acceptable to use these
                 products in combination.                             Insulation must be protected from open flame
                                                                      and kept dry at all times.
             Mechanical Attachment
                                                                      Factory applied packaging is intended only for
                 When installing multiple layers (which may          protection during transit. Slit or remove the
                 include insulation, cover boards and thermal         packaging to prevent accumulation of
                 barriers) it is acceptable to mechanically secure    condensation.
                 through all layers.
                                                                      Store elevated (at least 3 inches) and
                 Use fasteners intended for use with this            completely covered with a weatherproof
                 product and that are supplied by or approved         covering such as a tarpaulin.
                 by Duro-Last, Inc.
                                                                      Do not use panels which are wet or damaged.
             Adhesive Attachment
                                                                      Refer to PIMA Technical Bulletin No. 109:
                 Insulation adhesive must be supplied by Duro-       Storage and Handling Recommendations for
                 Last, Inc. Refer to the adhesive’s product data      Polyiso Roof Insulation for additional guidelines
                 sheet for application guidelines. Acceptable         (www.pima.org).
                 products:
                            ®
                 o Duro-Grip  Insta-Stik™.                       Limitations:
                                    ®
                 o Duro-Grip Olybond .                                Duro-Last, Inc. will not be responsible or liable
                                                 ®
                 o Duro-Grip Millenium Weather-Tite .                 for any defects or problems related to building
                 o Duro-Grip CR-20.                                   or roof design by others, to deficiencies in
                                                                      construction, to dangerous conditions on the
                 Subsequent layers of insulation and approved        job site, or to improper storage, handling or
                 cover boards may be attached with insulation         installation by others.
                 adhesive.
                 Maximum panel dimensions are 4 ft. x 4 ft.

             Hot Bitumen Attachment
                 When using hot bitumen on concrete decks,
                 priming is necessary.
                 Temperature of the bitumen shall be
                 approximately 50° F below the inter-ply hand
                 mopping EVT.