                                                  DURO-GUARD  ISO III CG
            Installation:
                                                                             TABLE 2.  THERMAL VALUES
                 Panels must be kept dry before, during and
                 after installation. Install only as much insulation   THICKNESS*   LTTR      FLUTE SPANABILITY
                 as can be covered the same day with              inches   mm     R-VALUE      inches     mm
                                                                                    5.70
                                                                           25
                                                                                               2.625
                                                                   1.00
                                                                                                           67
                 completed roofing.                                1.50    38       8.60       4.375      111
                 The use of multiple layers of insulation with    1.60    41       9.10       4.375      111
                                                                                    9.70
                 joints staggered a minimum of 6 inches            1.70    43       11.40      4.375      111
                                                                                               4.375
                                                                   2.00
                                                                           51
                                                                                                          111
                 between layers is recommended to eliminate        2.50    64       14.40      4.375      111
                 thermal bridging.                                 2.70    69       15.60      4.375      111
                                                                   3.00    76       17.40      4.375      111
                 Butt panel edges together and stagger joints of
                 adjacent panels.                                  3.30    84       19.20      4.375      111
                                                                           89
                                                                   3.50
                                                                                                          111
                                                                                               4.375
                                                                                    20.50
                 Boards must be neatly fitted to roof deck and    3.60    91       21.10      4.375      111
                 around penetrations with no gaps greater than     4.00    102      23.60      4.375      111
                 ¼ inch.                                         * Contact Duro-Last for additional thickness options.

                 Refer to the appropriate Duro-Last roof system        TABLE 3.  TYPICAL PHYSICAL PROPERTIES
                 specification and detail drawings for deck                                             20 psi
                 preparation and attachment requirements.          Compressive   ASTM D 1621   Grade 2   (138 kPa)
                 Precautions must be taken to ensure that new      Strength    ASTM C 1289   Grade 3   25 psi
                 concrete decks have fully hydrated and do not                                         (172 kPa)
                 continue to release moisture.                     Dimensional   ASTM D 2126    2% linear change
                                                                    Stability
                                                                                                   (7 days)
            Panel Attachment:                                     Moisture Vapor   ASTM E 96       < 1 perm
                                                                                                           2
                                                                  Transmission                  (85.0 ng/Pa·s·m )
                 Panels may be attached to the roof deck using      Water
                 mechanical fasteners, insulation adhesive or      Absorption   ASTM C 209       < 1% volume
                 hot bitumen. It is acceptable to use these          Service                     -40° to 200° F
                 products in combination.                          Temperature                   (-40° to 93° C)
             Mechanical Attachment                                    To ensure embedment, the board shall also be
                 When installing multiple layers (which may          “stepped in” at several points while the bitumen
                 include insulation, cover boards and thermal         is still hot enough to allow positive attachment.
                 barriers) it is acceptable to mechanically secure      Maximum panel dimensions are 4 ft. x 4 ft.
                 through all layers.
                                                                      Any roof membrane contaminated with bitumen
                 Use fasteners and plates supplied by or             must be replaced.
                 approved by Duro-Last, Inc.
             Adhesive Attachment                                 Storage:
                 Insulation adhesive must be supplied by Duro-       Insulation must be protected from open flame
                 Last, Inc. Refer to the adhesive’s product data      and kept dry at all times.
                 sheet for application guidelines. Acceptable         Factory applied packaging is intended only for
                 products:                                            protection during transit. Slit or remove the
                            ®
                                      ™
                 o Duro-Grip  Insta-Stik .                            packaging to prevent accumulation of
                                    ®
                 o Duro-Grip Olybond .                                condensation.
                                                 ®
                 o Duro-Grip Millenium Weather-Tite .                 Store elevated (at least 3 inch) and completely
                 o Duro-Grip CR-20.                                   covered with a weatherproof covering such as
                                                                      a tarpaulin.
                 Subsequent layers of insulation and approved
                 cover boards may be attached with insulation         Do not use panels which are wet or damaged.
                 adhesive.                                            Refer to PIMA Technical Bulletin No. 109:
                 Maximum panel dimensions are 4 ft. x 4 ft.          Storage and Handling Recommendations for
                                                                      Polyiso Roof Insulation for additional guidelines
             Hot Bitumen Attachment                                   (www.pima.org).
                 When using hot bitumen on concrete decks,
                 priming is necessary.                           Limitations:
                 Temperature of the bitumen shall be                 Duro-Last, Inc. will not be responsible or liable
                 approximately 50° F below the inter-ply hand         for any defects or problems related to building
                 mopping EVT.                                         or roof design by others, to deficiencies in
                 The deck shall be dry and care must be taken        construction, to dangerous conditions on the
                 to apply the bitumen in sufficient quantity to       job site, or to improper storage, handling or
                 totally cover the available deck surface.            installation by others.

               www.duro-last.com                           2 of 2                              800-248-0280

                             Duro-Last, “World’s Best Roof”, Duro-Bond, Duro-Grip and Duro-Guard are registered marks owned by Duro-Last, Inc.
                                                Updated: 10/30/2013, 03/31/2014, 07/27/2016