                                                    DURO-GUARD  ISO II
            Installation:
                                                                             TABLE 2.  THERMAL VALUES
                 Panels must be kept dry before, during and      THICKNESS*                  FLUTE SPANABILITY
                                                                                   LTTR
                 after installation. Install only as much insulation   inches    mm   R-VALUE   inches    mm
                 as can be covered the same day with              1.00    25        5.70       2.625      67
                 completed roofing.                               1.50    38        8.60       4.375      111
                                                                  1.60    41        9.10       4.375      111
                 The use of multiple layers of insulation with   1.70    43        9.70       4.375      111
                 joints staggered a minimum of 6 inches           2.00    51       11.40       4.375      111
                 between layers is recommended to eliminate       2.50    64       14.40       4.375      111
                 thermal bridging.                                2.70    69       15.60       4.375      111
                                                                  3.00    76       17.40       4.375      111
                 Abut panel edges together and stagger joints of   3.30  84       19.20       4.375      111
                 adjacent panels.                                 3.50    89       20.50       4.375      111
                 Boards must be neatly fitted to roof deck and   3.60    91       21.10       4.375      111
                                                                  4.00
                                                                          102
                                                                                   23.60
                                                                                               4.375
                 around penetrations with no gaps greater than   * Contact Duro-Last for additional thickness options.   111
                 ¼ inch.
                 Refer to the appropriate Duro-Last roof system       TABLE 3.  TYPICAL PHYSICAL PROPERTIES
                 specification and detail drawings for deck                                 Grade 2     20 psi
                 preparation and attachment requirements.         Compressive   ASTM D 1621           (138 kPa)
                                                                    Strength   ASTM C 1289              25 psi
                 Precautions must be taken to ensure that new                              Grade 3   (172 kPa)
                 concrete decks have fully hydrated and do not    Dimensional   ASTM D 2126    2% linear change
                 continue to release moisture.                      Stability                     (7 days)
                                                                 Moisture Vapor                   < 1 perm
            Panel Attachment:                                     Transmission   ASTM E 96     (85.0 ng/Pa·s·m )
                                                                                                          2
                                                                     Water
                 Panels may be attached to the roof deck using    Absorption   ASTM C 209       < 1% volume
                 mechanical fasteners, insulation adhesive or       Service                     -40° to 200° F
                 hot bitumen. It is acceptable to use these       Temperature                   (-40° to 93° C)
                 products in combination.
                                                                      totally cover the available deck surface.
             Mechanical Attachment
                                                                      To ensure embedment, the board shall also be
                 When installing multiple layers (which may          “stepped in” at several points while the bitumen
                 include insulation, cover boards and thermal         is still hot enough to allow positive attachment.
                 barriers) it is acceptable to mechanically secure
                 through all layers.                                  Maximum panel dimensions are 4 ft. x 4 ft.
                                                                      Any roof membrane contaminated with bitumen
                 Use fasteners and plates supplied by or             must be replaced.
                 approved by Duro-Last, Inc.
                                                                 Storage:
             Adhesive Attachment
                 Insulation adhesive must be supplied by Duro-       Insulation must be protected from open flame
                 Last, Inc. Refer to the adhesive’s product data      and kept dry at all times.
                 sheet for application guidelines. Acceptable         Factory applied packaging is intended only for
                 products:                                            protection during transit. Slit or remove the
                                      ™
                            ®
                 o Duro-Grip  Insta-Stik .                            packaging to prevent accumulation of
                                    ®
                 o Duro-Grip Olybond .                                condensation.
                                                 ®
                 o Duro-Grip Millenium Weather-Tite .                 Store elevated (at least 3 inches) and
                                                                      completely covered with a weatherproof
                 o Duro-Grip CR-20.                                   covering such as a tarpaulin.
                 Subsequent layers of insulation and approved        Do not use panels which are wet or damaged.
                 cover boards may be attached with insulation
                 adhesive.                                            Refer to PIMA Technical Bulletin No. 109:
                                                                      Storage and Handling Recommendations for
                 Maximum panel dimensions are 4 ft. x 4 ft.
                                                                      Polyiso Roof Insulation for additional guidelines
             Hot Bitumen Attachment                                   (www.pima.org).
                 When using hot bitumen on concrete decks,      Limitations:
                 priming is necessary.
                                                                      Duro-Last, Inc. will not be responsible or liable
                 Temperature of the bitumen shall be                 for any defects or problems related to building
                 approximately 50° F below the inter-ply hand         or roof design by others, to deficiencies in
                 mopping EVT.                                         construction, to dangerous conditions on the
                 The deck shall be dry and care must be taken        job site, or to improper storage, handling or
                 to apply the bitumen in sufficient quantity to       installation by others.
               www.duro-last.com                           2 of 2                              800-248-0280

                                   Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
                                                    Updated: 10/31/2013, 07/27/2016