Page 78 - Microsoft Word - 2_Inch_Drain_Adapter_PDS_2016_01_05
P. 78

®
                  DURO-GUARD  EPS FIBERGLASS FACER
                                             FLAT AND TAPERED PANELS

            Description:
                      ®
            Duro-Guard  EPS Fiberglass Facer is a premium
            insulation consisting of a superior closed-cell,
            lightweight and resilient expanded polystyrene (EPS)
            which is factory laminated to a durable fiberglass
            facer. It meets or exceeds the requirements of ASTM
            C 578, Standard Specification for Rigid, Cellular
            Polystyrene Thermal Insulation.
                 Available in both flat and tapered panels in
                 order to meet thermal insulation needs as well
                 as provide slope for proper roof drainage.
                                                   ®
                 May be used directly under Duro-Last
                 membranes. This saves labor by eliminating
                 the need for installing a separate cover board   Figure 1. Duro-Guard EPS Fiberglass Facer (Top Layer)
                 or slip sheet.
                                                                 Tapered Panels:
                 Provides long-term thermal insulation value.
                 Does not contain CFCs or HCFCs.                    Typical sizes:
                Superior moisture resistance.                        o 4 ft. x 4 ft. (1220 mm x 1220 mm).
                100% recyclable.                                     o 4 ft. x 8 ft. (1220 mm x 2440 mm).
                                                                      o Thicknesses: 0 to 40 inch (0 to 1016 mm).
                 Type VIII, 1.25 pcf, per ASTM C 578.
                                                                      Precut cricket and saddle systems are
                 Refer to Table 3 for physical properties.
                                                                      available.
            Recommended Uses:                                         Taper designs and shop drawings are
                                                                      available.
                 Mechanically attached Duro-Last roof systems.       Custom sizes are available.
                Duro-Bond  roof systems.
                           ®
                 Metal retrofit roof systems.
                 Adhered Duro-Last membranes.

            Underwriters Laboratories Inc:
                 May achieve UL Class A fire rating on
                 noncombustible decks without the use of a       Figure 2. Duro-Guard EPS Fiberglass Facer Taper
                 cover board. Refer to Duro-Last’s UL Listings
                 (TGFU.R10128) for assembly details
                 (www.ul.com).                                        TABLE 1. TYPICAL TAPER PANEL DIMENSIONS
                                                                    ID          SLOPE*             Thickness
            Factory Mutual Global:                                 A1      ⅛” per 12”   1%
                                                                   A2      ⅛” per 12”   1%
                                              ®
                 Refer to FM Approval’s RoofNav  for details on   A3      ⅛” per 12”   1%
                 FM Approved systems (www.roofnav.com).            A4      ⅛” per 12”   1%      EPS panels can be
                                                                   C1      ¼” per 12”   2%     formed up to 40” thick.
                                                                   C2      ¼” per 12”   2%
            Flat Panels:                                           C3      ¼” per 12”   2%     The starting thickness of
                                                                                               the tapered panels can
                Typical sizes:                                    C4      ¼” per 12”   2%    be custom ordered based
                                                                    E1     ½” per 12”   4%     on project requirements.
                 o 4 ft. x 4 ft. (1220 mm x 1220 mm).               E2     ½” per 12”   4%
                 o 4 ft. x 8 ft. (1220 mm x 2440 mm).               E3     ½” per 12”   4%
                                                                    E4     ½” per 12”   4%
                 o Thickness: Up to 40 inch (1016 mm).           * Contact Duro-Last for additional slope options.


               www.duro-last.com                            1 of 2                             800-248-0280
                  Duro-Last, “World’s Best Roof”, Duro-Bond, Duro-Grip, Duro-Fleece, Duro-Fleece Plus, Duro-Tuff and Duro-Guard are registered marks owned by Duro-Last, Inc.
                                                RoofNav is a registered mark owned by FM Global.
                                           Created: 01/17/2012 Revised: 03/19/2013, 11/04/2013, 05/05/2015
   73   74   75   76   77   78   79   80   81   82   83