                                               DURO-GUARD  EPS NAIL BASE
                                                                   •   Subsequent layers of insulation and approved
            Installation:                                             cover boards may also be attached with
              •   Duro-Guard EPS Nail Base may be used                insulation adhesive.
                 directly under the Duro-Last membrane.            •  Maximum panel dimensions are 4ft. x 4ft.
                 Care should be taken to ensure that “bare”
                 EPS is never in direct contact with the
                 membrane. Refer to the appropriate Duro-
                 Last specification for slip sheet and cover     TABLE 2.  TYPICAL PHYSICAL PROPERTIES (FOAM CORE)
                 board requirements.                                 Property         Test    Type II   Type VIII
              •   Panels must be kept dry before, during and                        Method
                 after installation. Install only as much insulation   Density       ASTM     1.50 pcf   1.25 pcf
                 as can be covered the same day with                 (nominal)       C 303
                 completed roofing.                                   R-Value        ASTM
                                                                     (per inch)
              •   The use of multiple layers of insulation with       @25°F          C 518      4.76     4.55
                 joints staggered a minimum of 6 inches               @40°F            or       4.55     4.25
                 between layers is recommended to eliminate           @75°F          C 177      4.17     3.92
                 thermal bridging.
                                                                   Compressive
              •   Butt panel edges together and stagger joints of    Strength        ASTM     15 – 21   13 – 18
                 adjacent panels.                                (10% deformation)   D 1621     psi       psi
              •   Boards must be neatly fitted to roof deck and                      ASTM
                 around penetrations with no gaps greater than    Flexural Strength   C 203   ≥ 35 psi   ≥ 30 psi
                 ¼ inch.                                            Dimensional      ASTM
              •   Refer to the appropriate Duro-Last roof system     Stability      D 2126          ≤ 2.0%
                 specification and detail drawings for deck         Water Vapor
                 preparation and attachment requirements.           Permeance      ASTM E 96      ≤ 3.5 perm
              •   Precautions must be taken to ensure that new                       ASTM
                 concrete decks have fully hydrated and do not   Water Absorption    C 272          ≤ 3.0%
                 continue to release moisture.
                                                                   Flame Spread    ASTM E 84         20
            Panel Attachment:                                    Smoke Developed  ASTM E 84       150 - 300
              •   Panels may be attached to the roof deck using
                 mechanical fasteners or insulation adhesive.  It   Storage:
                 is acceptable to use these products in
                 combination.                                      •   Insulation must be protected from open flame
                                                                      and kept dry at all times.
             Mechanical Attachment
                                                                   •   Factory applied packaging is intended only for
              •   When installing multiple layers (which may          protection during transit. Slit or remove the
                 include insulation, cover boards and thermal         packaging to prevent accumulation of
                 barriers) it is acceptable to mechanically secure    condensation.
                 through all layers.
                                                                   •   Store elevated (at least 3”) and completely
              •   Use fasteners intended for use with this            covered with a weatherproof covering such as
                 product and that are supplied by or approved         a tarpaulin.
                 by Duro-Last, Inc.
                                                                   •   Do not use panels which are wet or damaged.
             Adhesive Attachment
              •   Insulation adhesive must be supplied by Duro-
                 Last, Inc. Refer to the adhesive’s product data   Limitations:
                 sheet for application guidelines. Acceptable      •   Duro-Last, Inc. will not be responsible or liable
                 products:                                            for any defects or problems related to building
                            ®
                 o Duro-Grip  Insta-Stik™.                            or roof design by others, to deficiencies in
                            ®
                                     ®
                 o Duro-Grip  Olybond .                               construction, to dangerous conditions on the
                                                  ®
                            ®
                 o Duro-Grip  Millenium Weather-Tite .                job site, or to improper storage, handling or
                            ®
                 o Duro-Grip  CR-20.                                  installation by others.



               www.duro-last.com                           2 of 2                              800-248-0280

                                   Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
                                                       Updated: 11/4/2013