                                          DURO-GUARD  EPS TYPES II, VIII AND IX

            Installation:                                        Storage:
                 Duro-Guard EPS panels and Duro-Last                 Insulation must be protected from open flame
                 membrane must never be in direct contact.            and kept dry at all times.
                 Refer to the appropriate Duro-Last specification      Factory applied packaging is intended only for
                 for slip sheet and cover board requirements.         protection during transit. Slit or remove the
                 Panels must be kept dry before, during and          packaging to prevent accumulation of
                 after installation. Install only as much insulation   condensation.
                 as can be covered the same day with
                 completed roofing.                                       TABLE 2. TYPICAL THERMAL VALUES
                 The use of multiple layers of insulation with        Thickness*             R-Value
                 joints staggered a minimum of 6 inches              Inches     mm    Type II   Type VIII   Type IX
                 between layers is recommended to eliminate           1.00     25      4.5      4.2      4.7
                 thermal bridging.                                    1.50     38      6.7      6.3      7.0
                                                                      2.00     51      9.0      8.4      9.4
                 Abut panel edges together and stagger joints of     2.50     64     11.2      10.5     11.7
                 adjacent panels.                                     3.00     76     13.5      12.6     14.1
                                                                      3.50     89     15.7      14.7     16.4
                 Boards must be neatly fitted to roof deck and       4.00    102     17.0      16.8     18.8
                 around penetrations with no gaps greater than        4.50    114     20.2      18.9     21.1
                 ¼ inch.                                              5.00    127     22.5      21.0     23.5
                                                                      5.50    140     24.7      23.1     25.8
                 Refer to the appropriate Duro-Last roof system      6.00    152     27.0      25.2     28.2
                 specification and detail drawings for deck          * Contact Duro-Last for additional thickness options.
                 preparation and attachment requirements.
                 Precautions must be taken to ensure that new          TABLE 3.  TYPICAL PHYSICAL PROPERTIES
                 concrete decks have fully hydrated and do not
                                                                                  Test
                 continue to release moisture.                       Property    Method   Type II   Type   Type IX
                                                                                                  VIII
                                                                     Density     ASTM
            Panel Attachment:                                       (nominal)    C 303   1.50 pcf   1.25 pcf   2.00 pcf
                                                                     R-Value
                 Panels may be attached to the roof deck using     (per inch)   ASTM
                 mechanical fasteners or insulation adhesive. It     @25°F       C 518    4.76    4.55     5.00
                                                                                   or
                 is acceptable to use these products in              @40°F       C 177    4.55    4.25     4.76
                 combination.                                        @75°F                4.17    3.92     4.35
                                                                   Compressive
             Mechanical Attachment                                   Strength    ASTM    15 – 21   13 – 18   25 – 33
                                                                      (10%
                 When installing multiple layers (which may       deformation)   D 1621   psi     psi     psi
                 include insulation, cover boards and thermal                    ASTM
                 barriers) it is acceptable to mechanically secure   Flexural Strength  C 203   ≥ 35 psi   ≥ 30 psi   ≥ 50 psi
                 through all layers.                               Dimensional   ASTM
                                                                     Stability   D 2126      ≤ 2.0%       ≤ 2.0%
                 Only use fasteners and plates supplied by, or
                 approved by, Duro-Last, Inc.                      Water Vapor   ASTM E 96   ≤ 3.5 perm   ≤ 2.0 perm
                                                                    Permeance
             Adhesive Attachment                                 Water Absorption  ASTM      ≤ 3.0%       ≤ 2.0%
                 o Insulation adhesive must be supplied by                       C 272
                   Duro-Last, Inc. Refer to the adhesive’s         Flame Spread   ASTM E 84    20          20
                   product data sheet for application guidelines.    Smoke      ASTM E 84   150 - 300    150 - 300
                   Acceptable products:                             Developed
                                      ™
                            ®
                 o Duro-Grip  Insta-Stik .
                                    ®
                 o Duro-Grip Olybond .                                Store elevated (at least 3 inches) and
                                                                      completely covered with a weatherproof
                                                 ®
                 o Duro-Grip Millenium Weather-Tite .                 covering such as a tarpaulin.
                 o Duro-Grip CR-20.                                   Do not use panels which are wet or damaged.
                 Subsequent layers of insulation and approved
                 cover boards may also be attached with          Limitations:
                 insulation adhesive.
                                                                      Duro-Last, Inc. will not be responsible or liable
                 Maximum panel dimensions are 4 ft. x 4 ft.          for any defects or problems related to building
                                                                      or roof design by others, to deficiencies in
                                                                      construction, to dangerous conditions on the
                                                                      job site, or to improper storage, handling or
                                                                      installation by others.
               www.duro-last.com                           2 of 2                              800-248-0280

                             Duro-Last, “World’s Best Roof”, Duro-Grip, Duro-Bond and Duro-Guard are registered marks owned by Duro-Last, Inc.
                                          Created: 01/17/2012   Revised: 03/19/2013, 11/04/2013, 03/04/2014