                                  DURO-SHIELD  ACRYLIC MAINTENANCE ROOF COATING


            INSTALLATION:                                         6.  Coating
            1.  General                                              a.  Stir until an even consistency is achieved. A

              Only apply product when the ambient                      slow-speed drill with mixer attachment is
               temperature is between 50º F (10° C) and 95º             recommended.
               F (35° C). Product must be stored between 60º         b.  For proper coverage, product must be applied
               F (15° C) and 80º F (26° C) for 24 hours prior           in 2 coats. Apply first coat at approximate
               to installation.                                         coverage rate of 67 square feet per gallon.

              Do not apply when rain, cold or nightfall are         c.  Allow to dry completely. Refer to drying times
               imminent. Relative humidity must be below 80%.           on product data sheet.
              In extreme hot, windy, or dry conditions, wet the     d.  Apply second coat perpendicular to first coat
               surface to be coated with a fine mist of clean           and at approximate coverage rate of 67
               water just before applying Duro-Shield Acrylic           square feet per gallon.
               Maintenance Roof Coating.
                                                                     e.  Allow to dry completely. Refer to drying times
              Thinning the product is not allowed.                     on product data sheet.
              Use a brush, roller (1-inch nap, min.), or airless   CLEANUP:
               sprayer to apply. Best results are obtained when     Uncured product may be removed by wiping with
               using an airless sprayer. Care should be taken        warm water, soap and a clean cloth.
               when using an airless sprayer to apply Duro-
               Shield products. Wind-blown over-spray may           Application equipment should be cleaned
               damage property adjacent to the project site.         immediately after use with warm water, soap and
                                                                     a clean cloth.
            2.  Substrate Preparation

               a.  Repair, if necessary, the substrate by
                  following Substrate Preparation instructions
                  within the Duro-Shield Maintenance Roof
                  Coating Installation Guide.
            3.  Cleaning Procedures

               a.  Apply to surfaces which are clean, dry and
                  free of oil, mildew, grease or any other
                  contaminants. Follow Cleaning Procedures
                  within the Duro-Shield Maintenance Roof
                  Coating Installation Guide.

            4.  Seam Treatment
               a.  Repair, if necessary, all horizontal and vertical
                  seams by following Seam Treatment
                  instructions within the Duro-Shield
                  Maintenance Roof Coating Installation Guide.
            5.  Priming
               a. Follow Priming instructions within the Duro-
                  Shield Maintenance Roof Coating Installation
                  Guide.

















             www.duro-last.com                              2 of 2                                800-248-0280