       ANSI STANDARD




       For Cut Resistance                                          New Testing Standard
       ANSI/ISEA 105 (2016 edition)
                                                                   The new edition of the ANSI/ISEA 105 Standard (2016 ed.) also
       The American National Standards Institute (ANSI) has released a new   outlines a new test method for determining the new cut scores.
       edition of the ANSI/ISEA 105 standard (2016 ed.). The changes include   The new ASTM F2992-15 test method allows for only one type
       new classification levels, which includes a new scale to determine cut   of machine to be used, the TDM-100. Under the previous ANSI
       score (commonly referred to as the ANSI cut score), and a revised   standard, the old test method ASTM F1790-05, the testing could
       method for testing gloves to the standard.                  be performed on either the TDM-100 machine or the CPPT
                                                                   machine. By ensuring uniform testing with one machine, it is
                                                                   easier to compare gram scores for a given material.
       New Scale to Determine Cut Scores
       The new ANSI standard now features nine cut levels   1
       significantly reducing the gaps between each level and
                                                        Old
       better defining protection levels for the cut resistant   Shield Icon
       gloves and sleeves with the highest gram scores.
       The graph below shows the differences between the
       old scale and the new scale. New ANSI cut scores will   1                                       CPPT MACHINE
       feature an "A" in front of the score.
                                                        New
                                                      Shield Icon
       7000g+
                 OLD
       6500g                                                                   TDM-100 MACHINE
                 NEW                                      6000
       6000g                                          5999
       5500g                                                       Understanding ASTM F2992-15
       5000g                                      4999  5000
                                                                   Test Methods
       4500g
       4000g                                  3999  4000           The sample is cut by a straight-edge blade, under load, that
                                3499   3500                        moves along a straight path. The sample is cut five times each at
       3500g
       3000g                              2999  3000               three different loads with a new blade for each cut and the data
                                                                   is used to determine
       2500g                              2200                     the required load
                                   2199
       2000g                                                       to cut  through  the
       1500g             2199 2199 1500 1500                       sample at a specified
                                                                   reference difference.
       1000g       999  999  1000 1000                             This is referred to                           BLADE
       500g  499  499  500  500                                    as the cutting force,                          Travel
            200  200
                                                                                                                   Test
       0g                                                          which is then equated                         Material
                                                                   to a cut level.
             1   1  2  2   3  3  4   4  5   5   6   7  8   9
   1   2   3   4   5   6   7   8   9   10   11