Page 36 - EOSedge installation Documents
P. 36
EOS 90396-A-PHY-0003-Columns assembly
1. Objective - This document describes and illustrates how to identify, transport and install the main
columns in the system using a custom-made tool called the “Column Transport Tool” (CTT). This
tool is capable of lifting, transporting, inclining and finally erecting the columns onto the Nivell
plates.
2. Prerequisites - Nivell plates already installed and levelled
3. Tools:
a. Specially designed column transportation and rotation tool (CTT)
b. 2X High precision levels (inclinometers)
c. 2X Center positioning bars
d. Displacement tool
4. Observations - When attaching the Lateral column to the CTT, you will need to remove the guide-
band (curtain) bottom bracket for proper transportation.