Page 337 - B6118-AEW-XX-XX-PP-A-0001_(P19)_Contractors Manual
P. 337

CONSTRUCT













         C2.8 Site Signage; Marketing Suite

         All signage will  be supplied  and installed  free     Regardless of type of sign, an electrical duct
         issue by Butterfield Signs.                            route  must be cast in the centre  of each sign
                                                                mass concrete foundation. Butterfield signs will
         The  ‘marketing’  signage  suite  is  any  signage     free issue a female socket terminal for McDrive
         other than DOT type signs and includes banner          sign required. The  principal contractor  must
         signs, all drive thru lane signage, height restrictor   draw an appropriate external electrical supply
         signs, welcome, exit and freestanding directional      to each sign, terminated with the female socket
         signs plus long range road signs. As set out in the    terminal. The supply  for each sign must have
         design section.                                        200mm slack cable above finished ground level
                                                                for final connection.
         The  type,  layout  and  quantity  of  signs will be
         indicated in the designer’s drawings and must          The site specific signage will be set out on the
         be installed  by the  principal contractor.  The       designer’s signage setting out  drawing. The
         mass concrete  foundations  for  future  sign          dimensions indicated will be from the centre of
         positions must be -100 / 150mm below local             tuning forks where appropriate.
         finished  ground  level  with  the  surface  finish
         running continuously over the top.                     Where road signage is being altered, or ground
                                                                works carried out around an existing road sign
         Signage is  installed via  free issue root  cages      then the foundations must be detailed so that
         which should be cast into mass concrete                the anchor bolts remain above ground and are
         foundations. The root cages will be free issued        readily available for regular visual inspections.
         to  the  principal contractor  for  their  installation
         on to the mass concrete foundations. The mass
         concrete  foundations  must be -100 / 150mm
         below  local  finished  ground  level  to  allow
         surface finishes over.



         All foundations must be adequately cured and
         all ground finishes reinstated prior to Butterfield
         Signs installing the signs over the exposed ends
         of the tuning forks.


         Where     difficult   ground     conditions    are
         experienced,  site  specific  design  must  be
         sought for all  signage but especially  the road
         signs. Concrete mix to be suitably specified to
         suit allowed curing window within the contract
         programme.