CONSTRUCT













          Wall Panels

          All laminate panels  must be fully  balanced to       All laminate wall panels must be fully bonded to
          a 12mm MDF core.  The  feature  laminate as           the wall behind plus mechanically fixed.
          specified  on  the  designer’s  drawings  must  be
          on  the  visible  face,  however,  the  balancing     Tight to skirting head level, a full length aluminium
          laminate to the rear of the panel can be              U trim must be installed for the laminate wall
          the  contractor’s  choice to  provide the  most       panels to  sit  into.  The  aluminium trim  must  be
          cost  effective  solution.  Laminate  finishes  are   Gooding Aluminium, ref GL PLT 1303 in SAA finish
          documented  in  the  design  section  of  this        and  mechanically  fixed  back  to  the  wall  at
          manual.                                               min 600 ctrs. The laminate wall board must be
                                                                rebated  at  the  bottom  rear  edge  to  sit tightly
                                                                into the U trim.
























































          C3.5           Laminate Wall Panels                 3.0                        23 June 2016