Page 470 - B6118-AEW-XX-XX-PP-A-0001_(P15)_Contractors Manual_Neat
P. 470

CONSTRUCT





       C3 Shopfitting






       C3.25  Self Order Kiosks                               Wall Mounted

       The location and type of self order  kiosks will       Wall mounted units to be mechanically fixed to
       be  identified  on  the  architect’s  site  specific   the wall using all available location holes in the
       drawings and ordered  by McDonald’s for  the           unit fixing plate. Weights of wall mounted SOK’s
       principal  contractor  to call  off. Regardless of     may vary dependant  on  manufacturer;  but
       supplier there are two general types:                  are generally 100kg each; principal contractor
                                                              to check supplied weight and ensure that the
       Freestanding                                           mounting  wall  is  suitably  constructed  to  fix  to,
                                                              including:
       Freestanding units to be mechanically fixed to
       the floor using all available location holes in the    -  Stud size and centres
       unit base plate. Above the ceiling, restraint must
       be installed to the head of the units utlising the     -  Restraint to soffit
       same detail as furniture screen fixing.
                                                              -  Wall linings
       Small power (1x) and data (4x) must be provided
       to this location (left coiled up below the ceiling)    Upgrade works to be undertaken as appropriate.
       by the principal contractor to coincide with its
       fixing post.                                           Small power (2x) and data (2x) must be provided
                                                              to this location by the principal contractor within
       Floor mounted kiosks are generally 140kg each.         the wall void.

                                                              Installation to be in line with the following:
                                                              -  Acrelec NGK Installation Guide N-E-B
                                                                01-A-12008-001 REV 1.0
                                                              -  Acrelec NGK Installation Guide N-E-B
                                                                01-A-12008-001 REV 2.0
                                                              -  Acrelec Wall NGK Installation Guide N-E-F
                                                                01-A-12008-002 REV 1.0
                                                              -  Acrelec Kit Installtion Guide K113017005-1 Rev
                                                                1.0
                                                              -  Acrelec NGK32” Pre Installtion V1.0 (14.03.14)
                                                              -  Kiosk Floor Fed Dependencies




















        C3.25          Self Order Kiosks                   3.0                        25 July 2017
   465   466   467   468   469   470   471   472   473   474   475