2.5 Ceilings
                            D R A F T


       2.5.1 Acoustic                                        Detail 1
       In  order  to  satisfy the  requirements  of  Part  E   New  acoustic  insulation  and  fire protection to
       (Resistance to sound) of the Building Regulations,    existing  timber  floor  (existing  ceiling  retained)
       it  is  necessary  to  install  an  acoustic  ceiling  in   between  new  A5  use  at  ground  floor  and
       virtually every store where there is occupation       existing residential use at first floor:
       on  a  first  floor  above  us.    The  only  exceptions
       being:                                                N.B. If existing ceiling is lath and plaster, this should be
                                                             supported by chicken wire securely fixed to underside of
       •  Where  we  have  sufficient    detail    of  the    joists.
          construction of a modern building to prove
          the acoustic properties of the concrete slab       Ceiling  upgraded  to  give  improved  airborne
          above us, or                                       sound insulation, 60 minutes Fire Resistance and
       •  Where  a  landlord  or  previous  tenant  has      Class O Surface Spread of Flame.
          already  installed,  or  is  legally committed
          to  installing, acoustic separation.               •  Gypliner  Universal  ceiling  suspended  with
                                                                 Gypframe  GL1  Lining  Channels  at  450mm
       However  both  of  these  circumstances  will  be         maximum  centres  to  give  a  preferred
       exceptions  rather  than  the  rule  and a new            minimum  cavity  of  50mm  (maximum  of
       acoustic ceiling should normally be installed to          145mm).
       the underside all occupied first floors.              •  50mm Isover APR 1200 insulation in the cavity
       An acoustic ceiling will typically be an MF ceiling       (no ductwork within void).
       with insulating quilt above it, as detailed below     •  Ceiling  lining  to  be  2  layers  of  12.5mm
       This will reduce the effective ceiling height by          Gypsum Fireline with taped and filled joints.
       upto  145mm  and  this  needs  to  be  taken  into
       account.                                              N.B. If there is no existing ceiling in place (i.e. joists exposed),
                                                             then the new construction above should be upgraded to
       Please  note  that  we  have  agreed  a  set  of      include 100mm thick Isover APR 1200 insulation.
       standards  for  acoustic/fire  ceilings  with  BRCS
       Building Control, for England and Wales.
       ( It is possible that Scotland/N.I./ROI may have
       different requirements and this must be borne
       in mind.)

       There  are  three  standard  agreed  options,
       depending  on  the  existing  user  classes  and
       building  construction,  and  ONE  of  these  MUST
       ALWAYS be used unless specifically agreed for
       the building in question.