       2.5.3 Timber Ceiling Beams
       102 x 50mm timber ceiling beams will be installed
       in random lengths and a pattern to match the
       setting out of the feature timber wall as noted
       on  the  project  drawings.  The  dimensions  and
       setting  out  of  the  ceiling  beams  should  also
       follow these rules;

       1.  The  bottom  of  the  beams  must  never  be
          lower  than  2250mm,  If  the  ceiling  is  lower
          than 2300mm AFFL the ceiling beams should
          be omitted.
       2. The beams must always be 50mm deep.

       The  timber  ceiling  beams  will  be  supplied  by
       Paradigm  and  are  to  be  made  from  20mm
       Engineered  Oak  Flooring,  mitred  and  glued,
       finished  with  20%  lacquer.  The  beams  will  be
       mechanically  fixed  to  9mm  MDF  hanging
       pattresses, secured on site to

       Beams  are to be provided in two standard
       lengths of 1900mm and 3800mm but can be cut
       on site, providing varying beam lengths to suit the
       project drawings. The 3800mm beams consist of
       two 1900mm beams joined together by 150 x 60
       x 20mm solid timber jointing pattresses.