2.7 Counters
                            D R A F T




       Counters  will  be  supplied  as  a  joinery  item  for    The contractor MUST consult the franchisee prior
       installation  by  the  Principal  Contractor.  Typical   to  placing  an  order  for  a  particular  counter
       counter details and construction drawings are         option. Contractor is to install the appropriate
       available  from  Paradigm,  Domino’s  approved        counter,  slap  table  front/sneeze  screen  as
       counter supplier.                                     shown indicated on the approved drawing.


       There  are two  distinct versions of  the  counter    The slap table front must be positioned to ensure
       design, commonly referred to as the ‘lowered’         the ceramic tiles on the face of the counter are
       option with a low level  collect area, and the        6mm BEHIND the base of the routed line on the
       ‘security’ option with a continuous glass shelf.      slap table front (when fitted). The applied 6mm
                                                             thick black line running across the face should
       Within  England  and  Wales,  the  ‘security          be  read  as  one  line  together  with  the  routed
       counter’ can be installed either with or without      line on the slap table front, with no steps in it.
       a  two-way  drawer,  depending  on  the  store
       layout: in stores where there is a door between       Standard drawings of the counter options can
       the Bake & Serve area and the customer area,          be  found  in  here  including  the  appropriate
       the ‘security counter’  can be used without           Sneeze  Screen counter front  (These directly
       a  two-way  drawer,  as  the  door  adjacent  to      relate to the joinery manufacturers order form).
       the counter will allow staff to meet and greet
       customers in wheelchairs. In stores where there
       is no door directly linking these two areas, the
       counter MUST include either a lowered section,
       or a two-way drawer.
       Note: sites in Scotland, Northern Ireland and Eire will require
       a lowered section  counter  or  a security counter  with a
       drawer.


       The glass shelf on the ‘security’ version is 320mm
       wide and will require  a cross  section  bar to
       provide support. It is imperative that this part of
       the post support system is installed. Failure to do
       so could result in the glass breaking along the
       length.  These cross supports are supplied by the
       joinery suppliers as part of the installation pieces.