               HYD-Calibration Kit Q&A
               Q: What is the warranty period on the HYD-Cal Kit?
               A: 1 year.
               Q: How many calibration kits are needed?
               A: One per site.
               Q: Can Cal Kits be used for more than one calibration?
               A: Yes, but, it depends on how many sensors are in the system.
               Q: Are different size kits available?
               A: Yes. A smaller kit containing 34L of hydrogen gas and a larger kit containing 103L.
               Q: When would you use the larger kit?
               A: The larger kit is recommended when you have more than 4 sensors to allow for multiple calibrations.
               Q: What is included in the calibration kit?
               A: The calibration kit include the gas and necessary adapters to enable flow of gas from the cylinder to the sensor.
                   •   34 liter cyl 50% prop/air
                   •   Reg with gauge and knob
                   •   Cal Cup
                   •   Screwdriver
                   •   Fixed calibration system
                   •   Case and tubing

               HYD-Sensor (LEL Direct Connect) Q&A
               Q: Why is this considered a Direct Connect sensor?
               A: The connection between the sensor and the monitor is directly connected using 2-wires and does not need power cables to
               run.
               Q: What is the benefit of the Direct Connect Sensor?
               A: Lower Cost.
               Q: What is the warranty period on the HYD-Sensor (LEL)?
               A: 1 year.
               Q: What type of sensor is the LEL Direct Connect sensor?
               A: Catalytic combustion with molecular sieve
               Q: How many sensors are needed with the HYD-Sensor (LEL)?
               A: See “Hydrogen Gas Monitor Product and Features Selector Guide”.
               Q: What is the maximum distance that the sensor can be
               mounted from the monitor?
               A: The maximum distance the HYD-Sensor can be mounted from the monitor is 1,000 ft. with a 16 AWG (gauge) Wire, 2,000 ft.
               with 14 AWG (gauge) Wire.
               Q: Can sensors be purchased to monitor other gases?
               A: Yes. Sensors are available for LEL, H2, O2, CO, and H2S

               HYD-H2 Q&A
               Q: What is unique with the HYD-H2 sensor?
               A: It will only sense hydrogen gas?
               Q: What is the warranty period on the HYD-H2?
               A: 1 year.
               Q: How many sensors are needed with the HYD-H2?
               A: See “Hydrogen Gas Monitor Product and Features Selector Guide”.
               Q: When would the HYD-H2 be selected for use?
               A: The HYD-H2 would be selected when specified by the engineer or when additional explosive gases may be present.
               Q: What is the maximum distance that the sensor can be mounted from the monitor?
               A: The maximum distance the HYD-H2 can be mounted from the monitor is 5,000 ft. with a 16 AWG (gauge) Wire, 8,000 ft. with
               14 AWG (gauge) Wire.

               Neutralizing Absorbent Pillow Q&A
               Q: How much electrolyte does a Nabpill absorb?
               A: A Nabpill absorbs 2 quarts of electrolyte.