Page 90 - PRATIKTO-BETON-KINERJA-TINGGI
P. 90
Tabel 4.3 Index segregasi [4]
Tabel 4.4 Klasifikasi Beton SCC[4]
Test Method Performance
criteria
High-flow SCC Super-high-flow SCC
Slump flow test Flow > 650 mm Flow > 750 mm
V-funnel test T < 15 sec T < 8 sec
J-Ring test Reduction in flow Reduction in flow < 100
< 100 mm mm
Height difference Height difference < 20
< 20 mm mm
(measured using (measured using J-ring
J-ring with with
bar clearance of bar clearance of 40 mm)
60 mm)
Sieve segregation < 20% < 15%
test
ALAT UJI BETON SCC
Selain alat kerucut Abrams, dapat digunakan beberapa alat lain
seperti :
1. L –Box
2. V-funnel test
3. J-Ring
70