Page 73 - (KU)01-75GAJ-1.5 - Change 1
P. 73

INTRO


   EP'S                                                              (KU)01-75GAJ-1.5                 A     FIGURES


                                                  1.2.2 CAUTIONS                                      B
                                                                                                             ACAWS
                                    Alert/Condition                     Crew Action
                              LOX QTY LOW                                                             C
                             The liquid oxygen quantity is   Use portable oxygen bottles if required.       GROUND
                             below 2.5 liters.                                                        D
                              LSGI NP 1 (2, 3 or 4) HI                                                      TAKEOFF
                             LSGI is selected and NP         HSGI.......................................... Select  E
                             LV !    IRU PRUH WKDQ
                             seconds.                        If high winds are present:                     FIRE/SMK
  NORM                                                       Change aircraft heading.                 F

                                                             LSGI........................................... Select
                                                                                                     G      PRES/OXY
                                                             If the ACAWS reoccurs:

                                                             HSGI.......................................... Select  H  ENG/PROP
                                                                LSGI is not available.
                              MAIN AC BUS OFF*                                                        I
                             Main ac bus is off.             GENERATOR switch (No. 3)............ Of           FUEL
                                                             If the ACAWS does not clear:             L

                                                             6 MAIN AC BUS MCBs.........................       AAR
                                                             ..................................... Reset (if open)  M
  SPEC                              NOT FOR FLIGHT                                                             ELEC
                                                                (AFT 245, LWR AC)
                                                             %XV VWDWXV PD\ DOVR EH YHUL¿HG E\        N
                                                             reviewing the ECBU bus page for the
                                                             affected bus.                                     HYD
                                                                                                     O
                                                             If the bus does not recover:
                                                             GENERATOR switch (No. 3).................      FLT CTRL
                                                             ..................................... Do not turn ON  P
                                                             Alternate Fuel Management procedure....
                                                             ........................................... Accomplish  R  GEAR
                                                             Fault Log.................................. Review
                              MAIN AV AC BUS OFF*                                                     S     DOR/RMP
  PERF                        The inverter has failed. Main   Fault Log.................................... Review
                              Avionics ac bus is off.                                                 T     JETTISON
                              MAIN DC BUS OFF*

                              Main dc bus voltage is less    TR 2 MAIN DC MCB.... Reset (if open)     U
                              than 22 volts and the Main ac     (P AFT R3 #4)                               LANDING
                              bus is not off or Essential ac
                              bus is not off.                TR 4 MAIN DC MCB.... Reset (if open)     V
                                                                (CP AFT R4 #2)                              DITCHING
                                                             If the ACAWS does not clear:
                                                             AVIONIC BAT CONT MCB....................  W
                                                             ... Pull, unless landing within 30 minutes     BAILOUT
                                                                (P FWD R2 #7)                         X