Page 426 - SEC_2017WorkingDocument_Neat
P. 426

MO     CAPE      CAPE 2018 U2        How the SO can be clarified?      Status in
                 DU      2018        SO which                                           final syllabus
                 LE      SO #       needs to be
                  #                more clearly
                                       stated
                                 and electrolytes.

                1       2.1      compare Ohmic      use IV graphs to compare an         Not Changed
                                 and non Ohmic      Ohmic device [eg. metallic          to suggested
                                 devices using an  conductor at constant
                                 IV graph           temperature] and non Ohmic
                                                    devices        [eg. semiconductor
                                                    diode and filament lamp].
                1       2.2      sketch the         This has already been put in        Not Changed
                                 variation of       Unit1 Module 1 SO 1.4:              to suggested
                                 resistance with     “Plot a calibration graph using a
                                 temperature for    thermistor”.
                                 a thermistor
                                 with negative      Unit1 Module 1 SO 1.4 could be
                                 temperature        changed to:
                                 coefficient;       Sketch the R-T characteristics for
                                                    both a negative and positive
                                                    temperature coefficient
                                 Also include       thermistor.
                                 different types of
                                 thermistors and    SUGGESTED PRACTICAL
                                 discuss the        ACTIVITIES Plot a R-T
                                 differences        calibration graph using a
                                 between the R –    negative temperature coefficient
                                 T                  thermistor.
                                 characteristics.

                                                    In Unit 2 Module 1, thermistors
                                                    could be included in SO 2.1
                                                    under the IV characteristics for
                                                    negative temperature coefficient
                                                    thermistors
                1       2.9      use the potential  Do you mean Potentiometer as a      Not Changed
                                 divider as a       potential divider [using a metre    to suggested
                                 source of          wire instead of 2 separate resistors
                                 variable and       in series]in order to get a  variable
                                 fixed p.d.;        p.d.?     OR
                                  Potentiometer,  Do you mean a metre bridge
                                 for example, a     Potentiometer used to compare
                                 meter bridge.      emfs?



                                                                                                       81
   421   422   423   424   425   426   427   428   429   430   431