Page 291 - CRESTRON HOME OS-3
P. 291

Crestron Home result after
                 Original Deploy      Configurator Changes    Crestron Home Changes
                                                                                        Redeploy
                                                              Add:                    Renamed:

                                                                  Load: Sconce 3          Load: (local) Sconce
                                                                  Device:                 3
                                                                  CLW-DIMFLVEX            Device:
                                                                                          CLW-DIMFLVEX

               The following changes were made:

                    l Crestron Home Configurator: Add load named "Sconce 3" controlled by a
                     CLW-DIMFLVEX in "Room A".
                    l Crestron Home Setup App: Add load named "Sconce 3" controlled by a CLW-DIMFLVEX in
                     "Room A".
               Results after Redeploy:

                    l A load named "Sconce 3" controlled by the CLW-DIMFLVEX is added to "Room A".
                    l The load named "Sconce 3" controlled by the CLW-DIMFLVEX in "Room A" is renamed to
                     "(local) Sconce 3".

               Update Min/Max for a Load in the Configurator and Crestron Home
                                            Configurator       Crestron Home      Crestron Home result after
                 Original Deploy
                                            Changes            Changes            Redeploy
                 Room A                                                           Room A
                     Load: Sconce 1                                                   Load: Sconce 1
                     Device: CLX-1DIMU4                                               Device: CLX-1DIMU4
                     (Output 1)                                                       (Output 1)

                     Load: Sconce 2         Update:            Update:            Updated:
                     Device: CLX-1DIMU4
                                                Min: 20%          Min: 35%            Min: 20%
                     (Output 2)
                                                Max: 90%          Max: 85%            Max: 90%

               The following changes were made:
                    l Crestron Home Configurator: Update the Min/Max level for the CLX-1DIMU4 to 20/90%.

                    l Crestron Home Setup App: Update the Min/Max level for the CLX-1DIMU4 to 35/85%.
               Results after Redeploy:

                    l The Min/Max level for the CLX-1DIMU4 (Output 2) is updated to 20/90%.

               A Device is Deleted in the Configurator and Crestron Home
                                      Configurator        Crestron Home        Crestron Home result after
                 Original Deploy
                                      Changes             Changes              Redeploy
                 Room A                                                        Room A






                Product Manual — Doc. 8525Z                                              Crestron Home™ OS • 291