Page 852 - CRESTRON HOME OS-3
P. 852

o Wired light load performance when controlling Lutron loads via Crestron Home
                           keypad programming and Scenes:
                               n Loads are controlled in the order that the cabinet is wired.
                               n There is a 0.1 second delay between each load that is controlled.

                               n Twenty loads in a cabinet can be controlled in approximately 1 to 2 seconds.
                               n Loads in multiple cabinets are controlled one cabinet at a time. For example, if
                                 there are two cabinets installed, loads in Cabinet A are controlled and then
                                 loads in Cabinet B are controlled.
                           o Wireless light load performance when controlling Lutron loads via Crestron Home
                           keypad programming and Scenes:
                               n There is a small delay (about 0.8 seconds) between each light load that is
                                 controlled.
                               n Controlling five wireless lights will take about 4.5 seconds.
                               n Controlling 27 wireless lights will take about 17 seconds.

                           o Wired and wireless shade load performance when controlling Lutron loads via
                           Crestron Home keypad programming and Scenes:

                               n There is a small delay between each shade load that is controlled.
                               n When controlling 20 shades, there will be a 1- to 3-second lag between when
                                 the first shade starts moving and the last shade starts moving.
                    l To emulate a Lutron button and a function within Crestron Home (for example, a Crestron
                     Home scene), create a sequence that recalls the Lutron button and the Crestron Home
                     function. For details, refer to Mode: Sequence (on page 143).
                    l Lutron loads can be included in a Quick Action when Scene or Sequence is selected from
                     the Mode drop-down menu.

                           o To control the Lutron load when Scene is selected from the drop-down menu, create
                           a scene that includes the Lutron load and then select the scene when configuring the
                           Quick Action. For details, refer to Step 4: Create Scenes (on page 114) and Mode:
                           Scene (on page 139).
                           o To control a Lutron load when Sequence is selected from the drop-down menu, add
                           the Lutron load to the sequence and then configure it. For details, refer to Mode:
                           Sequence (on page 143).
                    l Lutron shades will be excluded from Crestron Home shade groups. Lutron shade groups
                     should be setup in the Lutron Designer software. Crestron Home will create shade loads
                     for Lutron shade groups, and ungrouped shades.
















                Product Manual — Doc. 8525Z                                             Crestron Home™ OS • 835