Page 906 - CRESTRON HOME OS-3
P. 906
CAME Door Station with AVLINKPRO
Configure CAME door stations to communicate with a Crestron Home processor, TSW-xx60
series touch screens, and an AVLINKPRO. The TSW-xx60 series touch screens register to the
AVLINKPRO as SIP users. The primary CAME door station acts as a mini server (primary) and
allows the AVLINKPRO and secondary CAME door station to register to it.
Overview
The network topology for the Crestron Home processor and TSW-xx60 series touch screens to
interop with the CAME door stations is shown below.
The system was tested using the following components:
l Crestron Home processor (version 2.4362.12407)
l AVLINKPRO (16.2c)
l (3) Crestron TSW-xx60 series touch screen (version 2.7.60)
l Crestron Toolbox™ software
l CAME MTMV/IP Door Station (Primary) (version 2.5.3)
l CAME DVC/IP Door Station (Secondary) (version 2.5.3)
l PCS/XIP Design Tool Software (version 6.1.4)
NOTE: A computer is required to use Crestron Toolbox™ software and the PCS/XIP Design Tool
software.
Summary
The Video Door Entry system uses the AVLINKPRO as a server/PBX. In this setup, the
AVLINKPRO registers as a SIP Client to the primary CAME door station (MTMV/IP). The
Crestron TSW-xx60 series touch screens register to the AVLINKPRO.
Product Manual — Doc. 8525Z Crestron Home™ OS • 889