Page 17 - UL_Report On_Part 1
P. 17

11 IITGN-UL/Façade  12 IITGN-UL/Façade




 (b) engulfed in  (c) fire propagation                                                    This can be due  to lack of available provisions and  dearth  of appropriate
 (a) before fire
 smoke and fire  through façade   THE FREQUENCY AND SEVERITY                              testing and certification mechanisms. Thus, it is essentially to develop this
                                                                                          capacity in the academic and industrial outfits within India, especially in the
                           OF PAST FIRE ACCIDENTS                                         wake of 100+ smart cities being planned by Government of India in the next

                                                                                          few years.
           INDICATE LACK OF AWARENESS                                                     The associated cladding materials like the Medium Density Foam (MDF) and


          OF THE AVAILABLE RATING AND                                                     Aluminum Composite Panels (ACP) add a new dimension  to  the problem.
                                                                                          Also, in case of fire event, the performance of façade as well as the fire stop

              TESTING MECHANISMS IN THE                                                   material is crucial for  the overall performance of  the building.  Thus,
                                                                                          assessment of façade systems in real fire scenarios is important. Keeping this
                            INDIAN CONSTRUCTION                                           in mind, Underwriters Laboratories & IIT Gandhinagarhave constructed a full
                                                                                          scale G+2 story steel frame building within the campus of IIT Gandhinagar
                      INDUSTRY AND PUBLIC, IN                                             located in Gujarat, India, where different façade systems can be tested under
 (d) entire façade  (e) fate of the  (f) fate of                                          real fire scenarios. The building has three fire compartments in each story of
 collapsed during fire  façade  the building                                              plan dimensions 10'×20' with a storey height of 10’. Fire scenarios are
                                                             GENERAL.                     developed using real office furniture (sofa sets, reception desks, curtains,


                                                                                          carpets, etc.) in accordance with  the National Building Code of India. The
                                                                                          building has been instrumented with K-type  thermocouples, video and
                                                                                          thermal imaging cameras.
















 CHENNAI  TEXTILE SHOWROOM FIRE OF JUNE 1, 2017
   12   13   14   15   16   17   18   19   20   21   22