Page 19 - UL_Report On_Part 1
P. 19

13 IITGN-UL/Façade  14 IITGN-UL/Façade




 2. Capabilities and objectives


 THE G+2 STORY STEEL FRAME STRUCTURE BUILT UP AT IIT   fire stop                                                  fire stop

 GANDHINAGAR AS A JOINT VENTURE OF    deck slab                    façade                           deck slab                  façade

 UNDERWRITERS LABORATORIES AND IIT GANDHINAGAR

 can be used for full scale testing of façade assemblies under fire.
 This test facility is capable to serve the following objectives:



                                                                                                                             3  fire
                                                                                                                                spreads to
                                                                                                                                next floor
 To assess fire                                                   3  fire
 To study glass   behavior with                                      spreads to
 break behavior in   To study fire stop   ACP/MDF (or other          next floor
 real fire scenario  material in real   materials) being used                                      1  Fire starts
 fire scenario                       1  Fire starts
 with glass
                                                                                                                             2  fire stop


 To assess impact of                                   2   glass breaks                                                         material fails
 fire spread on   To assess out of
 structural   plane behavior of
 components   masonry walls
 (beams, columns)                 (a) External                                                    (b) Internal


 To assess  To study fire
 To assess smoke   performance of fire   spread behavior in
 obscuration   proofing &   buildings with façade   FIGURE 2: MECHANISMS OF FIRE SPREAD IN FAÇADE SYSTEMS
 levels  structural fire   (internal/external fire
 protection material  spread mechanism)
   14   15   16   17   18   19   20   21   22   23   24