Page 29 - Catalogue ANGLAIS 2016_Neat
P. 29
Prestressing dynamometer model VW3 & VW6
CHARACTERISTICS
Range load:
1000, 1500, 2500, 3500 kN
Accuracy :
2% de la pleine échelle
Height:
210 mm
Internal diameter:
125 mm
Exterior diameter :
250 mm
APPLICATIONS Temperature of use :
The anchor load cell model VW6 serves to check the applied loads Min -20°C
to the cables of prestressing cables and prestressed ties. Max +60°C
it is used for: Sinusoidal listened signal:
The control of cables equipping prestressed works (bridges, extra 10 to 30 mV efficacity
height of dams, nuclear power plants …).
The control of prestressed ties (temporary or definitive) of walls.
DESCRIPTION
Sinusoidal sustained signal :
150 to 170 mV efficacity sinusoïdal
The load cell VW3 and VW6 consists of a steel ring in which is
machined respectively 3 and 6 vibrating wire sensors distributed
uniformly and symmetrically. Any radial force applied to the ring is
transmitted by a variation of deformation of the load all vibrating Coils resistence : > 80 Ω
wire. The load cell is connected to the readout unit through a
connector and a cable. The load cell is located around the cable to
be inserted between the cable head and the bearing surface of the
Exit : basis 19 leads
civil work.
Options :
If the surface of the civil work is irregular, a pair of distribution
Other possible dimensions
plate is added to ensure a good distribution of the load. (On request only)
Advantages: Accessories :
Longevity and reliability thanks to the measurement by vibrating link cable
wire in sustained mode Rotary switch
Readout unit
High resolution and accuracy
Distribution plates
Signal transmission over large distances.
This document is on no account contractual; Géo-instrumentation reserves the right to modify its products and its data sheets without advance notice
Géo-Instrumentation - S.A.S. au capital de 37000 € - RCS Créteil B502768427 – APE : 7490B - N°TVA : FR10502768427