Page 144 - Select Specialty
P. 144

Oil-Less Claw Medical Vacuum


            Appendix B: Variable Speed Drive Inverter



            B.2.2   Parameter List (continued)

                                                                                      Minimum
                                                                                       Setting     Initial   Factory
             Function Parameters              Name                 Setting Range     Increments    Value    Setting
                                   Second acceleration/
                           44                                    0 to 3600/360s        0.1/0.01s      5s
                                   deceleration time
                           45      Second deceleration time      0 to 3600/360s, 9999     0.1/0.01s     9999

                           46
                                                                                         0.1%
                  uctuations   47    Second torque boost         0 to 30%, 9999         0.01Hz       9999
                                                                 0 to 400Hz, 9999
                                   Second V/F (base frequency)
                                                                                                     9999
                                   Second stall prevention
                                                                                         0.1%
                 Second fl   48     operation current             0 to 120%              0.01Hz      110%
                                   Second stall prevention
                           49
                                                                 0 to 400Hz, 9999
                                                                                                     0Hz
                                   operationfrequency
                                    Second output frequency
                           50                                     0 to 400Hz            0.01Hz       30Hz
                                   detection
                                   Second electronic thermal O/L    0 to 500A, 9999/0 to
                           51                                                          0.01/0.1A     9999
                                   relay                        3600A, 9999
                                                                 0, 5, 6, 8 to 14, 17,
                                    DU/PU main display data
                           52                                   20, 23 to 25, 50 to 57,    1          0
                                   selection                    100
                 Monitor functions   54     CA terminal function selection     1 to 3, 5, 6, 8 to 14,    0.01Hz     60Hz    133.3
                                                                                                      1
                                                                                           1
                                                                17, 21, 24, 50, 52, 53
                           55
                                    Frequency monitoring reference    0 to 400Hz
                                                                                                    Rated
                           56       Current monitoring reference     0 to 500A/0 to 3600A     0.01/0.1A    inverter
                                                                                                   output
                                                                                                   current
               Automatic   resart   functions   57     Restart coasting time     0, 0.1 to 5s, 9999/ 0,    0.1s     9999
                                                                0.1 to 30s, 9999
                           58
                                                                                                      1s
                                                                                         0.1s
                                                                 0 to 60s
                                    Restart cushion time
                ----      59        Remote function selection     0, 1, 2, 3               1          0
                ----      60        Energy saving control selection     0, 4, 9            1          0
                ----       65       Retry selection              0 to 5                    1          0
                                    Stall prevention operation
                ----       66                                    0 to 400Hz             0.01Hz       60Hz
                                   reduction starting frequency
                                    Number of retries at alarm
                           67                                    0 to 10, 101 to 110       1          0
                                   occurrence
                 Retry     68       Retry waiting time           0 to 10s                0.1s         1s

                           69       Retry count display erase     0                        1          0







                                                             B-5                                  4107 9000 95.04
   139   140   141   142   143   144   145   146   147   148   149