Oil-Less Claw Medical Vacuum


           Appendix B: Variable Speed Drive Inverter



           B.2.2   Parameter List (continued)

                                                                                     Minimum
                                                                                      Setting     Initial   Factory
            Function Parameters              Name                 Setting Range     Increments    Value    Setting
                                  Backlash acceleration stopping
                         140     frequency                      0 to 400Hz             0.01Hz       1Hz
                Backlash measures   141     Backlash acceleration stopping    0 to 360s     0.01Hz     0.5s
                                                                                        0.1s
                                 time
                                  Backlash deceleration stopping
                         142
                                                                0 to 400Hz
                                                                                                    1Hz
                                 frequency
                         143      Backlash deceleration stopping    0 to 360s           0.1s        0.5s
                                 time
                                                                0, 2, 4, 6, 8, 10, 102,
              ----       144      Speed setting switchover                               1           4
                                                               104, 106, 108, 110
              ----       145      PU display language selection     0 to 7               1           1
                                  Stall prevention level at 0V
              ----       148                                    0 to 120%               0.1%       110%
                                 input
                                  Stall prevention level at 10V
              ----       149                                    0 to 120%               0.1%       120%
                                 input
              ----       150      Output current detection level     0 to 120%          0.1%       110%
                                  Output current detection signal
              ----       151                                     0 to 10s               0.1s         0s
                                 delay time
              ----       152      Zero current detection level     0 to 150%            0.1%        5%
              ----       153      Zero current detection time     0 to 1s               0.01s       0.5s

                                  Voltage reduction selection
              ----       154     during stall prevention        0, 1                     1           1
                                 operation
                                  RT signal function validity
              ----       155                                    0, 10                    1           0
                                 condition selection
                                  Stall prevention operation
              ----       156                                    0 to 31, 100, 101        1           0
                                 selection
              ----       157      OL signal output timer        0 to 25s, 9999          0.1s         0s
                                                                1 to 3, 5, 6, 8 to 14,
              ----       158      AM terminal function selection                         1           1
                                                               17, 21, 24, 50, 52, 53
                                  Automatic switchover frequency
              ----       159     range from bypass to inverter     0 to 10Hz, 9999     0.01Hz      9999
                                 operation
              ----       160      User group read selection     0, 1, 9999               1           0
                                  Frequency setting/key lock
              ----       161                                    0, 1, 10, 11             1           0
                                 operation selection








           4107 9000 95.04                                  B-8
   322   323   324   325   326   327   328   329   330   331   332