Page 328 - Womens Pavilion
P. 328

Oil-Less Claw Medical Vacuum


            Appendix B: Variable Speed Drive Inverter



            B.2.2   Parameter List (continued)

                                                                                      Minimum
                                                                                       Setting     Initial   Factory
             Function Parameters              Name                 Setting Range     Increments    Value    Setting
                                    Automatic restart after      0, 1, 10, 11              1          0
                          162
                Automatic restart   functions   163    selection     0 to 20s            0.1%        0%
                                   instantaneous power failure
                                                                                                      0s
                                                                                         0.1s
                                    First cushion time for restart
                          164
                                    First cushion voltage for restart
                                                                 0 to 100%
                          165       Stall prevention operation level    0 to 120%        0.1%       110%
                                   for restart
                                   Output current detection signal
                Current   detection  166  retention time          0 to 10s, 9999         0.1s        0.1s      1
                                   Output current detection
                          167
                                                                                           1
                                                                 0, 1
                                                                                                      0
                ----      168      operation selection
                                   Parameter for manufacturer setting. Do not set.
                ----      169
               Cumulative   monitor   clear  170  Watt-hour meter clear   0, 10, 9999      1         9999


                                                                                                     9999
                                                                                           1
                                   Operation hour meter clear
                          171
                                                                 0, 9999
                                   User group registered display/
                          172      batch clear                   9999, (0 to 16)           1          0
                 User group  173   User group registration        0 to 999, 9999           1         9999

                          174      User group clear               0 to 999, 9999           1         9999






























                                                             B-9                                  4107 9000 95.04