Page 375 - Womens Pavilion
P. 375

COMPACT ALARM
                                                                                              R = Remote/Local Sensors
                                                                                              C = Conversion Series
                        1 module =                          3 modules =
                        A2ADR-L-X                           A2ADR-L-XXXXXX
                        2 gang back box                     4 gang back box



                        1 module =                          4 modules =
                        A2ADR-L-XX                          A2ADR-L-XXXXXXXX
                        3 gang back box                     5 gang back box    A2ADR-L-XXXXXXXXXXXX


                        2 modules =                         4 modules =
                        A2ADR-L-XXXX                        A2ADR-L-XXXXXXXX
                        3 gang back box                     7 gang back box



                        1 module =                          5 modules =
                        A2ADR-L-XX                          A2ADR-L-XXXXXXXXXX
                        4 gang back box                     7 gang back box
                                                                                               The Letter “X” Denes
                                                                                               the Type of Gas:
                        2 modules =                         6 modules =
                        A2ADR-L-XXXX                        A2ADR-L-XXXXXXXXXXXX               Oxygen         =  O
                        4 gang back box                     7 gang back box
                                                                                               Medical Air    =  A
                                                                                               MedVac         =  V
                                                                      The Letter “L” Represents   Nitrous Oxide  =  2
        NOTE: Please specify the gang back box on each alarm.         the Langauge:            Nitrogen       =  N
                                                                                               Carbon
                                                                      U = English (NFPA)       Dioxide        =  C
                                                                      E  = English (CSA)       WAGD           =  W
                                                                      F  = French (CSA)        AGSS           =  E
                                                                      S  = Spanish (NFPA)      Instrument Air   =  I




                                                                               1      3     5     7      9    11
        Example: English NFPA - Oxygen, Medical Air, MedVac, Nitrous Oxide,
        Nitrogen, Carbon Dioxide = A2ADR-U-OAV2NC
                                                                               2      4     6     8     10    12





                                                                    “X’’ indicates the order of gases, as shown above.
        NEMA 4 ALARM



                                         A2MN-L-XX


         The Letter “L” Represents                             The Letters “XX” Denes the
         the Langauge:                                         Number of Functions:

         E  = English (CSA/NFPA)                               10  =  10 Functions
         F  = French (CSA)
         S  = Spanish (NFPA)                                   20  =  20 Functions


       26     Amico Pipeline