Page 374 - Womens Pavilion
P. 374

Model Numbers


        AREA ALARM                                                                            R = Remote/Local Sensors

                                                                                              C = Conversion
                   1 module =
                   A2AR-E-X
                   2 gang back box
                                                              A2AR-L-XXXXXX
                  1 module =
                  A2AR-E-X
                  3 gang back box                                                              The Letter “X” Denes
                                                                                               the Type of Gas:

                   2 modules =                     4 modules =                                 Oxygen         =  O
                   A2AR-E-XX                       A2AR-E-XXXX
                   3 gang back box                 5 gang back box                             Medical Air    =  A
                                                                                               MedVac         =  V
                     1 module =                    4 modules =     The Letter “L” Represents   Nitrous Oxide  =  2
                     A2AR-E-X                      A2AR-E-XXXX
                     4 gang back                   7 gang back box  the Langauge:              Nitrogen       =  N
                     box                                                                       Carbon Dioxide   =  C
                                                                   U = English (NFPA)
                     2 modules =                                                               WAGD           =  W
                     A2AR-E-XX                     5 modules =     E  = English (CSA)          AGSS           =  E
                     4 gang back                   A2AR-E-XXXXX    F  = French (CSA)
                     box                           7 gang back box                             Instrument Air   =  I
                                                                   S  = Spanish (NFPA)
                     3 modules =
                     A2AR-E-XXX                    6 modules =
                     4 gang back                   A2AR-E-XXXXXX
                     box                           7 gang back box
        Example: 4 Gases, English ISO, Remore/Local pressure sensors,
        Oxygen, MedVac, Medical Air and Nitrous Oxide = A2AR-E-OVA2
        NOTE: Please specify the gang back box on each alarm.

        MASTER ALARM


                         10 functions =                                                               C = Conversion
                         A2M-E-10                                  30 functions =
                         2 gang back box                           A2M-E-30
                                                                   4 gang back box  A2M(C)-L-20




                        10 functions =                             40 functions =
                        A2M-E-10                                   A2M-E-40
                        3 gang back box                            5 gang back box        The Letter “L” Represents
                                                                                          the Langauge:
                                                                   40 functions =         E  = English (CSA/NFPA)
                        20 functions =
                        A2M-E-20                                   A2M-E-40               F  = French (CSA)
                        3 gang back box                            7 gang back box
                                                                                          S  = Spanish (NFPA)


                        10 functions =                             50 functions =
                        A2M-E-10                                   A2M-E-50
                        4 gang back box                            7 gang back box



                        20 functions =
                        A2M-E-20                                   60 functions =
                        4 gang back box                            A2M-E-60
                                                                   7 gang back box

        Example:   2 Modules, English (20 Functions) = A2M-E-20
        NOTE: Please specify the gang back box on each alarm.
                                                                                                        www.amico.com     25
   369   370   371   372   373   374   375   376   377   378   379