Page 121 - UK Standard Products Catalogue 2018_23.10.18
P. 121
Glulam
Dimensional Information
Planted Root Option
Height BD BH TD WH TL PD DH x DW Mass OTM Shear Min. Concrete Dia.
(m) (mm) m) (mm) (m) (m) (mm) (mm) (kg) (kNm) (kN) (mm)
4 140 1,3 90 1,7 1,0 800 400 x 85 42 5,31 1,43 536
5 140 1,3 90 2,7 1,0 800 400 x 85 47 5,93 1,40 584
6 140 1,3 90 3,7 1,0 1000 400 x 85 53 5,83 1,29 295
Flange Plated Option
Height BD BH TD WH TL DH x DW SL x T x BC Anchor Mass OTM Shear Concrete Foundation
(m) (mm) (m) (mm) (m) (m) (mm) (mm) Bolts (kg) (kNm) (kN) Size (mm)
4 140 1,3 90 1,7 1,0 400 x 85 270 x 12 x 200 M14/16 x 300 36,5 5,31 1,43 400 sq x 700 h
5 140 1,3 90 2,7 1,0 400 x 85 270 x 12 x 200 M14/16 x 300 41,5 5,93 1,40 400 sq x 700 h
6 140 1,3 90 3,7 1,0 400 x 85 270 x 12 x 200 M14/16 x 300 45,5 5,83 1,29 400 sq x 700 h
Headload Capacity Information
Height (m) Mounting Arrangement Projection (m ) 2 Weight (kg) Extra Light Light Medium Heavy Extra Heavy
4 Post Top N/A 50 1,10 0,97 0,89 0,82 0,65
5 Post Top N/A 50 0,86 0,75 0,69 0,62 0,49
6 Post Top N/A 30 0,60 0,51 0,46 0,42 0,32
Dimensions and technical information given as an indication.
See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it
deems necessary to improve the products of the Standard Collection.