APPENDIX K
K104.3 Existing elevators. Existing elevators, escalators,
dumbwaiters and moving walks shall comply with the
requirements of Sections K104.3.1 and K104.3.2.
K104.3.1 Elevators, escalators, dumbwaiters and mov-
ing walks. Existing elevators, escalators, dumbwaiters and
moving walks in ambulatory care facilities required to be
separated by Section 422 of the International Building
Code shall comply with ASME A17.3.
K104.3.2 Elevator emergency operation. Existing eleva-
tors with a travel distance of 25 feet (7620 mm) or more
above or below the main floor or other level of a building
and intended to serve the needs of emergency personnel
for fire-fighting or rescue purposes shall be provided with
emergency operation in accordance with ASME A17.3.
SECTION K105
REFERENCED STANDARDS
ICC IBC—18 International Building Code K101.2
K102.1, K102.2,
K102.2.2, K102.2.3, K102.2.4,
K102.2.5, K102.2.6, K102.5.1,
K102.5.2.1, K102.5.2.2, K102.5.4,
K102.5.6, K103.1, K103.2,
K103.4.1, K103.4.2, K104.3.1
ASME A17.3— Safety Code for Existing Elevator K104.3.1,
2015 and Escalators K104.3.2