                                                   TABLE 1.3.2—continued
                                                   WOOD FRAME WALLS
                                                  4″ TO LESS THAN 6″ THICK
                                                            PERFORMANCE      REFERENCE NUMBER              REC.
         ITEM CODE THICKNESS      CONSTRUCTION DETAILS                                             NOTES
                                                            LOAD   TIME  PRE-BMS-92 BMS-92 POST-BMS-92    HOURS
                           2″ × 4″ stud wall;  / ″, 1:5; 1:7.5 lime    See                         17, 21,
                                        1
                     1
                                         2
         W-4-W-42   4 / ″  plaster on wood lath on both wall faces.   Note 23  30 min.      1       23     1 / 2
                      2
                                        1
                           2″ × 4″ stud wall;  / ″ thick 1:5; 1:7.5 lime
                                         2
                     1
         W-4-W-43   4 / ″  plaster on wood lath on both faces;    See   45 min.      1             17, 18,   3 /
                      2                                    Note 23                                 21, 23   4
                           insulated cavities.
                                        3
                           2″ × 4″ stud wall;  / ″ thick cement-asbes-
                                         16
                                  3
                     5
         W-4-W-44   4 / ″  tos over  / ″ thick gypsum board on both   See   1 hr.      1           23, 25,   1
                      8            8                       Note 23                                 26, 27
                           faces.
                           2″ × 4″ stud wall; studs faced with 4″ wide
                                                   3
                                 3
                     5
                                                    16
                                  8
         W-4-W-45   4 / ″  strips of  / ″ thick gypsum board;  / ″ thick   See   1 hr.      1      23, 25,   1
                      8
                                                                                                   27, 28
                           gypsum cement-asbestos board on both  Note 23
                           faces; insulated cavities.
                                                                   1 hr.
                     5
                                                                                                            1
         W-4-W-46   4 / ″  Same as W-4-W-45 but nonload bearing.   N/A  15 min.      1             24, 28  1 / 4
                      8
                                        3
                           2″ × 4″ stud wall;  / ″ thick cement-asbes-
                                         16
                     7
                                                                                                            1
                                      1
         W-4-W-47   4 / ″  tos board over  / ″ thick gypsum sheathing   See   1 hr.  1             23, 25,   1 /
                      8                2                   Note 23 15 min.                         26, 27    4
                           on both faces.
                                                                   1 hr.
                     7
                                                                                                            1
         W-4-W-48   4 / ″  Same as W-4-W-47 but nonload bearing.   N/A  30 min.      1             24, 27  1 / 2
                      8
                                                   3
                           2″ × 4″ stud wall; Exterior face:  / ″ wood
                                                    4
                                                      2
                           sheathing; asbestos felt 14 lbs./100 ft. and
                           5 / ″ cement-asbestos shingles; Interior   See                          18, 23,
         W-5-W-49    5″     32              3                     40 min.           1              25, 26,   2 /
                           face: 4″ wide strips of  / ″ gypsum board  Note 23                       29      3
                                             8
                                                  3
                           over studs;  wall faced with  / ″ thick
                                                   16
                           cement-asbestos board.
                           2″ × 4″ stud wall; Exterior face: as per W-
                                              9
                           5-W-49; Interior face:  / ″ composite
                                               16
                                          7
         W-5-W-50    5″    board consisting of  / ″ thick wood fiber-  See   30 min.      1        23, 25,   1 /
                                           16              Note 23                                 26, 30   2
                                       1
                           board faced with  / ″ thick cement-asbestos
                                        8
                           board; Exterior side exposed to fire.
         W-5-W-51    5″    Same  as W-5-W-50 but interior side   See   30 min.      1              23, 25,   1 /
                           exposed to fire.                Note 23                                  26      2
         W-5-W-52    5″    Same as  W-5-W-49 but  exterior side   See   45 min.      1             18, 23,   3 /
                           exposed to fire.                Note 23                                 25, 26   4
                                          3
                                           4
         W-5-W-53    5″    2″ ×  4″ stud  wall;  / ″  thick T&G wood   See   20 min.      1        17, 23  1 / 3
                           boards on both sides.           Note 23
                           Same as W-5-W-53 but with insulated    See                              17, 18,
         W-5-W-54    5″                                           35 min.           1                      1 /
                           cavities.                       Note 23                                  23      2
                                          3
                           2″ ×  4″ stud  wall;  / ″  thick T&G wood
                                           4
         W-5-W-55    5″    boards on both sides with 30 lbs./100 ft. 2    See   45 min.      1      17, 23  3 /
                                                           Note 23                                          4
                           asbestos; paper, between studs and boards.
                                         1
                           2″ × 4″ stud wall;  / ″ thick, 1:2; 1:3 gyp-
                                          2
         W-5-W-56    5″    sum plaster on metal lath on both sides of   See   45 min.      1       17, 21,   3 /
                                                           Note 23                                  34      4
                           wall.
                                                        (continued)
         218                                                            2018 INTERNATIONAL EXISTING BUILDING CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   232   233   234   235   236   237   238   239   240   241   242