Page 238 - ICC IEBC 2018
P. 238

RESOURCE A



                                                       TABLE 1.3.2—continued
                                                       WOOD FRAME WALLS
                                                      4″ TO LESS THAN 6″ THICK
                                                               PERFORMANCE       REFERENCE NUMBER             REC.
              ITEM CODE THICKNESS     CONSTRUCTION DETAILS                                             NOTES
                                                                LOAD   TIME  PRE-BMS-92 BMS-92 POST-BMS-92    HOURS
                                             3
                               2″ × 4″ stud wall;  / ″ thick 2:1:8; 2:1:12
                                              4
                                                                See
             W-5-W-57     5″   lime and Keene's cement plaster over   Note 23  45 min.      1          17, 21,   1 / 2
                                                                                                        23
                               metal lath on both sides of wall.
                                             3
                               2″ × 4″ stud wall;  / ″ thick 2:1:8; 2:1:10
                                              4
                                                                See
             W-5-W-58     5″   lime portland cement  plaster  over metal   Note 23  30 min.      1      17, 21,   1 / 2
                                                                                                        23
                               lath on both sides of wall.
                                            3
                                             4
             W-5-W-59     5″   2″ × 4″ stud wall;  / ″ thick 1:5; 1:7.5 lime   See   30 min.      1      17, 21,   1 /
                               plaster on metal lath on both sides of wall.  Note 23                    23      2
                               2″ × 4″ stud wall;  / ″ thick 1: / :2; 1: / :
                                                     1
                                                          1
                                            3
                                             4
                                                           30
                                                      30
             W-5-W-60     5″   3 portland cement,  asbestos  fiber plaster   See   45 min.      1      17, 21,   3 /
                                                               Note 23                                  23      4
                               on metal lath on both sides of wall.
                               2″ × 4″ stud wall;  / ″ thick 1:2; 1:3
                                            3
                                             4
             W-5-W-61     5″   portland cement plaster on metal lath on   See   30 min.      1         17, 21,   1 /
                                                               Note 23                                  23      2
                               both sides of wall.
                                             3
                                              4
                                                                                                                1
             W-5-W-62     5″   2″ × 4″ stud wall;  / ″ thick neat gypsum   N/A  1 hr.   1              17, 22,   1 /
                               plaster on metal lath on both sides of wall.   30 min.                   24       2
                                             3
                                              4
                                                                                                                1
             W-5-W-63     5″   2″ × 4″ stud wall;  / ″ thick neat gypsum   See   1 hr.  1              17, 21,   1 /
                               plaster on metal lath on both sides of wall.  Note 23 30 min.            23       2
                                             3
                               2″ × 4″ stud wall;  / ″ thick 1:2; 1:2 gyp-
                                              4
                                                                       1 hr.
                                                                See
                                                                                                                1
             W-5-W-64     5″   sum plaster on metal lath on both sides of   Note 23 30 min.  1         17, 18,   1 / 2
                                                                                                       21, 23
                               wall; insulated cavities.
             W-5-W-65     5″   2″ × 4″ stud wall; same as W-5-W-64 but   See   1 hr.      1            17, 21,   1
                               cavities not insulated.         Note 23                                  23
                               2″ × 4″ stud wall;  / ″ thick 1:2; 1:3
                                            3
                                             4
                                                                See
                                                                       1 hr.
                                                                                                                1
             W-5-W-66     5″   gypsum plaster on metal lath on both sides   Note 23 15 min.  1         17, 18,   1 / 4
                                                                                                       21, 23
                               of wall; insulated cavities.
                               Same as W-5-W-49 except cavity insula-
                               tion of 1.75 lbs./ft. mineral wool bats;    See   1 hr.                 23, 26,
                                             2
                                                                                                                1
                         1
             W-5-W-67   5 / ″                                                           1                      1 /
                               rating  applies when either wall side  Note 23 15 min.                   25
                          16                                                                                     4
                               exposed to fire.
                               2″ × 4″ stud wall,  / ″ thick 1:2; 1:3
                                            7
                                             8
                                                                       1 hr.
                                                                See
                          1
                                                                                                                1
             W-5-W-68    5 / ″  gypsum plaster on metal lath on both sides   Note 23 30 min.  1        17, 18,   1 / 2
                           4
                                                                                                       21, 23
                               of wall; insulated cavities.
                                             7
                               2″ × 4″ stud wall;  / ″ thick neat gypsum
                                              8
                                                                       1 hr.
                                                                                                                3
                          1
             W-5-W-69    5 / ″  plaster applied on metal lath on both sides   N/A  45 min.  1          17, 22,   1 / 4
                           4
                                                                                                        24
                               of wall.
                                             1
                               2″ × 4″ stud wall;  / ″ thick neat gypsum
                                              2
                                                                See
                                       3
                          1
             W-5-W-70    5 / ″  plaster on  / ″ plain gypsum lath on both   Note 23  1 hr.      1      17, 22,   1
                           4
                                        8
                                                                                                        23
                               sides of wall.
                                              1
                               2″ × 4″ stud wall;  / ″ thick of  1:2; 1:2
                                               2
                                             3
                               gypsum plaster on  / ″ thick plain gypsum   See                         17, 21,
                                              8
                                              3
                                        3
                          1
             W-5-W-71    5 / ″  lath with  1 / ″ × 1 / ″ metal lath pads   1 hr.        1                       1
                                               4
                           4
                                         4
                               nailed 8″ o.c. vertically and 16″ o.c.    Note 23                        23
                               horizontally on both sides of wall.
                                              1
                               2″ × 4″ stud wall;  / ″ thick of  1:2; 1:2
                                               2
                                             3
                               gypsum plaster on  / ″ perforated gypsum
                                              8
                                                                See
                          1
                                      3
             W-5-W-72    5 / ″  lath, one  / ″  diameter hole or larger per   Note 23  1 hr.      1      17, 21,   1
                           4
                                       4
                                                                                                        23
                               16″ square of lath surface, on both sides of
                               wall.
                                                            (continued)
             2018 INTERNATIONAL EXISTING BUILDING CODE ®                                                         219
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.