Page 276 - ICC IEBC 2018
P. 276

RESOURCE A



                                                            SECTION III
                                                   FLOOR/CEILING ASSEMBLIES
                                                             FIGURE 3.1
                                           FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE



               NUMBER OF                                                           The number in each box is
              ASSEMBLIES                                                           keyed to the last number in the
                                                                                   Item Code column in the Table.
                 10                                                                For example:

                                                                                           FC-7-RC-40
                                        49      50

                                        48      42

                                        23      39                            40

                             45         20      33                            36
                  5
                             44      46  18     21                            34
                             17      41  16     13                            29

                         43  14      19  10     11     35                     28

                         30   4      12  8      9      26                     25                            38

                          5   3  47  1   7  15  2      22      24      27  31  6      32                    37
                  0
                    0              1              2              3              4               5              6
                                                 FIRE RESISTANCE RATING (HOURS)




                                                            TABLE 3.1
                                          FLOOR/CEILING ASSEMBLIES—REINFORCED CONCRETE
                                                                  PERFORMANCE      REFERENCE NUMBER
                        ASSEMBLY                                                                               REC.
              ITEM CODE                 CONSTRUCTION DETAILS                                            NOTES
                       THICKNESS                                                                              HOURS
                                                                  LOAD   TIME  PRE-BMS-92 BMS-92 POST-BMS-92
                                 3
                                               1
                                 3 /   ″thick floor; 3 / ″  (5475 psi) concrete
                                   4
                                                4
                                     1
                                                      3
                                 deck;  / ″ plaster under deck;  / ″ main rein-
                                      2
                                                        8
                                                           7
                                               1
                                                            8
                                                2
                           3
              F/C-3-RC-1  3 / ″  forcement bars at 5 / ″ pitch with  / ″ con-  195 psf 24 min.          7  1, 2  1 /
                                          3
                            4    crete cover;  / ″ main reinforcement bars at                                    3
                                           8
                                                        1
                                 1
                                 4 / ″ pitch  perpendicular with  / ″ concrete
                                   2
                                                         2
                                 cover; 13′1″ span restrained.
                                 1
                                                           3
                                 3 / ″ deep (3540 psi) concrete deck;  / ″ main
                                                            8
                                   4
                                 reinforcement bars at 5 / ″  pitch with  / ″
                                                   1
                                                               7
                                                                8
                                                    2
                           1
                                      3
                                                               1
              F/C-3-RC-2  3 / ″  cover;  / ″ main reinforcement bars at 4 / ″ 195 psf 2 hrs.          7  1, 3, 4  2
                            4          8                        2
                                 pitch perpendicular  with  / ″  cover; 13′1″
                                                    1
                                                     2
                                 span restrained.
                                                            (continued)